If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
NEXT FIND IT Table of Contents CLICK FOR PDF FILE OVERVIEW - Inductive Proximity Sensors Introduction ........................................4 Operation ............................................5 CLICK FOR PDF FILE CYLINDRICAL Inductive Proximity Sensors Introduction/Operation .......................8 Selection Guide, DC styles................12 Selection Guide, AC styles ................14 Product Specifications......................16 LIMIT STYLE Inductive Proximity Sensors Introduction/Operation .....................68 Selection Guide.................................71 Product Specifications......................72 CLICK FOR PDF FILE BLOCK STYLE Inductive Proximity Sensors Introduction/Operation .....................80 Selection Guide.................................82 Product Specifications......................84 CLICK FOR PDF FILE RING STYLE Inductive Proximity Sensors Introduction/Operation .....................98 Selection Guide...............................100 Product Specifications....................102 CLICK FOR PDF FILE ACCESSORIES for Inductive Proximity Sensors Introduction ....................................113 Mounting Brackets .........................114 Cable Assemblies............................116 Switching Units...............................122 Motion Detectors............................128 OTHER INFORMATION APPENDIX: IP Codes .........................................132 NEMA requirements .......................133 Cross Reference .............................134 Glossary..........................................135 Conversion Charts ..........................137 INDEX .............................................138 TERMS & CONDITIONS .................141 WARRANTY....................................143 CLICK FOR PDF FILE All specifications subject to change without notice or obligation Altech Corp.(R) * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 3 PREVIOUS HOME NEXT FIND IT Cylindrical Sensors 8 Altech Corp.(R) * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 PREVIOUS CYLINDRICAL INDUCTIVE PROXIMITY SENSORS Altech Cylindrical sensors are available in diameters ranging from 4mm (.16 in.) to 30mm (1.18 in.) with sensing distances up to 40mm (1.57 in.). Most models feature nickel plated brass (BN) housing, but stainless steel (SS) and non-metallic versions are available. Both flush mount and non-flush mount sensors are available. Flush mount versions are often called shielded or embeddable. Non-flush mount sensors are also called non-shielded or nonembeddable. Non-flush sensors have larger sensing distances than their flush mount counterparts. All Inductive sensors meet IP67 (NEMA1, 3, 4, 6, 12, 13) protection levels. Please refer to pages 132-133 of this catalog for more information. HOME NEXT FIND IT Sensing Distances - AC, DC, Cylindrical Style Sensors Type L Series - Short Body GL Series - 2 LED Standard Series Extended Sensing Range High Speed Plastic & Metal Housing Mini Housing Complementary Output Extended Temperature Range Weld Immune Analog Output Extended Range Plus 2-Wire Namur Voltage DC DC AC, DC DC DC AC, DC DC DC DC AC, DC DC DC DC DC Flush* 1.5 - 10 2 - 10 1.5 - 10 2 - 15 2 2 - 10 0.8 - 1.5 2 - 10 2 - 10 2 - 10 0.5 - 4 3 - 22 2 - 10 2 - 10 4 - 15 4 - 15 4 - 15 7 - 14 6 - 40 4 - 15 4 - 15 4 - 15 Non-Flush* 2 - 15 4 - 15 2 - 15 3 FLUSH MOUNT CYLINDRICAL SENSORS Flush Mounted, sometimes called embedded or shielded sensors, have electromagnetic fields concentrated directly in front of the sensing heads and may be mounted directly into metal mounting brackets or embedded directly into metal without causing a false output. Figure 8 also illustrates that on Cylindrical Flush Mount sensors there should be at least 1 diameter of distance between adjacent sensors, and no non-target metal surfaces should be less than 3 times the sensing distance Sn directly across from the sensing head. Also, two directly opposite sensors mounted in metal should be greater than 6 times the sensing distance apart. *All Sensing Distances in mm. Operating Voltages - AC, DC Cylindrical Style AC DC 90 - 250VAC 18 - 30VDC 20 - 250VAC 10 - 30VDC 10 - 60VDC Operating Current- AC, DC Cylindrical Style AC DC 180 mA 5 mA 500 mA 120 mA 200mA 400 mA Sensor Wiring Systems - AC, DC Cylindrical Style AC DC 2-Wire 2-Wire 3-Wire 4-Wire Altech Corp.(R) * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 9 PREVIOUS NON-FLUSH CYLINDRICAL SENSORS Sometimes called non-embedded or non-shielded, non-flush sensors have electromagnetic fields with a wide sensing angle and are unshielded (no metal surrounding the sensing head). Care must be taken to insure that no non-target metal comes in near proximity to the sensing head. Distances are demonstrated in Figure 8. Adjacent sensors should be separated by at least 2 times the diameter. Non-target metal should be at least 3 times the sensing distance directly across from the sensing head. Two directly opposite sensors should be at least 6 times the sensing distance apart. OUTPUT CONNECTIONS AC,DC - Normally Open (NO), and Normally Closed (NC). DC Namur - Special interface Circuits required. DC Analog - Analog Output 1 to 9V. OUTPUT CABLES Cylindrical Sensors are provided with 2 meter PVC fixed cables. 5 meter PVC, 2 and 5 meter PUR cables are optional and specified by selection of the last two digits of the part number. See chart below. Cable Length & Material 2m PVC 5m PVC 2m PUR 5m PUR Part No. Last Digits 00 02 10 12 HOME NEXT FIND IT Fig. 8 CYLINDRICAL SENSOR INSTALLATION Flush Mount Installation (Mild Steel) D 3 x Sn D D Non-Flush Mount Installation (Mild Steel) 3 x Sn D D 2xD D D D Opposing Installation D (Mild Steel) 6 x Sn D Quick Disconnect models are designed to be user-friendly and to simplify installations. Please see the product specification for sensors with quick disconnect connectors and matching cable assemblies on pages 116 to 121 in the accessory section. QUICK DISCONNECT HOUSING MATERIALS CONNECTORS Pulostronic sensors are available in AC - Nickel Plated Brass Trogamid T a wide selection of Quick Teflon Plated Brass Disconnect styles for DC and AC circuits. While virtually any sensor DC - Nickel Plated Brass can be custom manufactured with a Trogamid T Quick Disconnect connector, Altech Teflon Plated Brass offers one of the largest selection of Stainless Steel standard Quick Disconnect models. 10 Altech Corp.(R) * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 PREVIOUS HOME NEXT FIND IT Altech Corp.(R) * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 11 PREVIOUS HOME NEXT FIND IT DC CYLINDRICAL SENSORS - SELECTION GUIDE Sensing Distance mm (in.) Series Size (mm) M8 M12 M18 M30 M12 M18 M30 M8 M12 M18 M30 M8 Extended Sensing 10-30V DC, 200mA * Up to 2x improvement over Standard M12 M18 M30 Metal & Plastic 10-30V DC, 400mA * Extended Length * Higher Current Output Mini Housing 10-30V DC, 200mA * 4, 5, 6.5mm diameter * Includes LED Complementary Switching Output 10-30V DC, 200mA * NO & NC Outputs High Speed 10-30V DC, 200mA * 4,000 Hz Switching Frequency Extended Temperature 10-30V DC, 200mA * -40C to 100C M12 M18 M30 4mm Dia. M5 6.5mm Dia. M12 M18 M30 0.8mm (.03 in.) 1.0mm (.04 in) 1.5mm (.06 in.) 2.0mm (.08 in.) 2.5mm (.10 in.) 3.0mm (.12 in.) 4.0mm (.16 in.) 5.0mm (.20 in.) 6.0mm (.23 in.) 7.0mm (.28 in.) 8.0mm (.32 in.) 10.0mm (.40 iin.) 12.0mm (.47 in.) L Series 18-30V DC, 120mA * Short Body * Economically priced GL Series 10-60V DC, 400mA * 2 LED's * NO & NC models Standard Series 10-30V DC, 200mA * Most quick disconnects * Industry standard * NO & NC models * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * M12 M12 M18 12 (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 PREVIOUS HOME NEXT FIND IT Mounting 14.0mm (.55 in.) 15.0mm (.59 in.) 20.0mm (.78 in.) 22.0mm (.86 in.) 40.0mm (1.5 in.) Flush Output Configuration PNP NO NC Connection Cable 2m (6ft.6in.) Quick Disconnect 62 63 64 65 Housing Material No. of Wires 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 Metal (BN) Brass Nickel Plated NonMetallic Non-Flush NPN No. of LED's Page 1 1 1 1 2 2 2 1 1 1 1 1 1 1 1 16 17 18 19 20 21 22 24 25 26 27 28 29 29 30 32 32/33 33 34 34 35 36 37 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * (ss) * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * 1 1 1 1 1 1 1 1 1 * * * * * * * * * 3 3 3 4 4 4 * * * * * * * * * * * 3 1 31 3 3 1 1 38 39 Continued on Page 14/15 (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 13 PREVIOUS HOME NEXT FIND IT DC CYLINDRICAL SENSORS - SELECTION GUIDE (Cont.) Sensing Distance mm (in.) Series Weld-Immune 10-30V DC, 200mA * Resistant to Electromagnetic Interference * Teflon Plated 2-Wire 5-30V DC, 100mA 10-55V DC, 200mA * Reduce Wiring * Lower Cost Extended Range Plus 10-30V DC, 200mA * Up to 3 times improvement over Standard Size (mm) M12 M18 M30 M12 M18 M30 M8 M12 M18 M30 0.8mm (.03 in.) 1.0mm (.04 in) 1.5mm (.06 in.) 2.0mm (.08 in.) 2.5mm (.10 in.) 3.0mm (.12 in.) 4.0mm (.16 in.) 5.0mm (.20 in.) 6.0mm (.23 in.) 7.0mm (.28 in.) 8.0mm (.32 in.) 10.0mm (.40 iin.) 12.0mm (.47 in.) * * * * * * * * * * * * * * * Namur Requires External Amplifier * Low Energy Device * Operates in Hazardous Areas Analog 18-30V DC, 5mA * 1-9V Linear Output * Detects Target Distance M8 M12 M18 M30 M12 M18 M30 * * * * * * * * * AC CYLINDRICAL SENSORS - SELECTION GUIDE Sensing Distance (mm/in.) Series Standard Series 90-250V AC, 180 mA * Large Selection of Quick Disconnects * NO or NC Outputs Extended Voltage, Metal 20-250V AC, 500 mA * High Current Output * NO or NC Outputs Extended Voltage, Plastic 20-250V AC, 500 mA * High Current Output * NO or NC Outputs Weld Immune 20-250V AC, 300/ 500 mA * Resistance to Electro magnetic interference * Teflon Plated Mounting 10mm 14.0mm 15.0mm (.40 in.) (.55 in.) (.59 in.) Flush Non-Flush Size 0.8mm (.03 in.) 1.5mm (.06 in.) 2.0mm (.08 in.) 2.5mm (.10 in.) 4.0mm (.16 in.) 5.0mm (.20 in.) 7.0mm (.28 in.) 8.0mm (.32 in.) Output Configuration NO NC M12 M18 M30 M12 M18 M30 M12 M18 M30 M12 M18 M30 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * 14 (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 PREVIOUS HOME NEXT FIND IT Mounting 14.0mm (.55 in.) 15.0mm (.59 in.) 20.0mm (.78 in.) 22.0mm (.86 in.) 40.0mm (1.5 in.) Flush Output Configuration PNP NO NC Connection Cable 2m (6ft.6in.) Quick Disconnect 62 63 64 65 Housing Material No. of Wires 3 3 3 2 2 2 3 3 3 3 2 2 2 2 3 3 3 Metal (BN) Brass Nickel Plated NonMetallic Non-Flush NPN No. of LED's 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 Page * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * 40 41 42 54 54 55 46 47 48 49 50 51 52 53 44 44 45 * * * * * * * * * * Connection Cable 62 66 67 68 No. of Wires (1) Housing Material Metal (BN) Plastic No. of LED's 1 1 1 1 1 1 Page 56 57 58/59 60 61 62/63 60 61 62/63 64 65 66 * * * * * * * * * * * * * * * * * * * * * * * * * * * 2 2 2 2 2 2 2 2 2 * * * * * * * * * * * * 1 1 1 1 1 1 * * * 2 2 2 (1) All metal sensors have a 3rd wire for optional system ground. (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 15 PREVIOUS DC - 3 WIRE - L SERIES Brass, Nickel Plated (BN), Cylindrical,Threaded, M8 - 10-30V DC, 200mA M12-M30 - 18-30V DC, 120mA 1 LED for Output Energized HOME NEXT FIND IT * Short Body Sensors * Economically priced * Connector options * Carries mark * IEC (529)IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection * Short Circuit Protection * Overload Protection * Reverse Polarity Protection * Wire Break Resistance * Temperature Range: -25 to 70C (-13 to 158F) M8 Flush Mount Sensing Distance Cable or Connector Style Cat. No. Cable 9981-2000 M8 Non-Flush Mount 2mm (.08 in.) 65 9981-2065 1.5mm (.06 in.) 64 9981-2064 Cable 9981-2200 64 9981-2264 65 9981-2265 PNP NPN Normally Open Normally Closed Normally Open Normally Closed 9981-2100 9981-2164 9981-2165 9981-2300 9981-2364 9981-2365 Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Current Switching Frequency Hysterisis Temperature Drift Repeatability Front Cap Material 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 2000Hz 15% 10% .15mm (.006 in.) PBTP 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 2000Hz 15% 10% .15mm (.006 in.) PBTP 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 2000Hz 15% 10% .15mm (.006 in.) PBTP 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 2000Hz 15% 10% .20mm (.008 in.) PBTP 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 2000Hz 15% 10% .20mm (.008 in.) PBTP 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 2000Hz 15% 10% .20mm (.008 in.) PBTP M M Fixed Cable PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.) cable length, change the last two digits of the part number to 02. For other cable lengths and/or PUR cable, please consult Altech. Non-metallic locknuts for M8 and Brass, Nickel Plated (BN) locknuts for M12 through M30. 8 x 1 8 x 1 LED LED 35 4 PORT LED 64 Style Connector 3-pin, Pico style, 8mm (.31 in.) supplied with non-metallic locknuts for M8 and Brass, Nickel Plated (BN) locknuts for M12 through M30. 4 PORT LED 50 29 50 M 8 x LED 2 40 4 x 1 1 50 1 23 5 12 x LED 65 Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with non-metallic locknuts for M8 and Brass, Nickel Plated (BN) locknuts for M12 through M30. 28 16 (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 50 5 M M 8 x 1 M 8 x 1 M M 12 x 1 8 35 M 8 x 1 M 8 x 1 30 5 PREVIOUS HOME NEXT FIND IT Accessories Metric/in. Conversion Table 1.0 mm 5.0 mm 6.0 mm 8.0 mm 12.0 mm 23.0 mm 24.0 mm 28.0 mm 29.0 mm = .04 in. = .20 in. = .23 in. = .31 in. = .47 in. = .91 in. = .94 in. =1.10 in. =1.14 in. 30.0 mm 34.0 mm 35.0 mm 39.0 mm 40.0 mm 50.0 mm = = = = = = 1.18 in. 1.34 in. 1.37 in. 1.53 in. 1.57 in. 1.96.in. 2 meter (6 ft. 6 in.) DC Cable Assemblies for Quick Disconnect Sensors This table converts millimeters to inches in reference to the illustrations included on these pages M12 Flush Mount 2mm (.08 in.) Cable 9982-2000 M12 Non-Flush Mount 4mm (.16 in.) 65 Cable 9982-2200 64 Connector 8000-5220 PVC, Straight 64 Connector 8000-5230 PVC, Right Angle, 2LED, PNP 64 Connector 8000-5240 PVC, Right Angle, 2LED, NPN 65 Connector 8000-5110 PVC, Straight 65 Connector 8000-5120 PVC, Right Angle 65 Connector 8000-5150 PVC, Right Angle, 2LED, NPN 65 Connector 8000-5160 PVC, Right Angle, 2LED, PNP Change last digit of connector number to 5 for 5 meter cable Refer to pages 116-121 for more cable information 64 9982-2064 64 9982-2264 65 9982-2265 9982-2065 Mounting Brackets - see Page 114-115 9982-2100 9982-2164 9982-2165 9982-2300 9982-2364 9982-2365 10% 18V - 30V 10 mA 120 mA 1.5V 10 A 2000Hz 15% 10% .20mm (.008 in.) PBTP 10% 18V - 30V 10 mA 120 mA 1.5V 10 A 2000Hz 15% 10% .20mm (.008 in.) PBTP 10% 18V - 30V 10 mA 120 mA 1.5V 10 A 2000Hz 15% 10% .20mm (.008 in.) PBTP 10% 18V - 30V 10 mA 120 mA 1.5V 10 A 1000Hz 15% 10% .40mm (.016 in.) PBTP 10% 18V - 30V 10 mA 120 mA 1.5V 10 A 1000Hz 15% 10% .40mm (.016 in.) PBTP 10% 18V - 30V 10 mA 120 mA 1.5V 10 A 1000Hz 15% 10% .40mm (.016 in.) PBTP Wiring Diagrams Note; Wire colors are applicable on cables purchased from Altech. Note: Sensor dimensions in mm. PNP Fixed Cable BR BK NPN Fixed Cable + BR M M 12 x 1 LED 12 x 1 + LOAD LOAD BK BL LED * 35 6 35 * BL - Normally Open - Normally Open M M 12 x 1 4 PORT LED 12 x 1 64 Connector 1 BR BK + 4- PORT LED 64 Connector 1 BR BK BL 3 - *+ LOAD 30 6 4 50 0 40 24 2/4 3 LOAD BL * - 2/4 M 50 6 30 24 4 50 0 40 (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 50 M 8 x 1 LED 8 x 1 Normally Open Normally Open M 12 x 1 LED M 12 65 Connector BR + 1 65 Connector BR 1 x 1 2 * + LOAD 4 BK LOAD 3 4 BK * BL - 2 3 BL - M 12 x 1 M 12 x 1 Normally Open Normally Open 17 PREVIOUS DC - 3 WIRE - L SERIES Brass, Nickel Plated (BN), Cylindrical,Threaded, 18-30V DC, 120mA 1 LED for Ouput Energized HOME NEXT FIND IT * IEC (529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection * Short Circuit Protection * Overload Protection * Reverse Polarity Protection * Wire Break Resistance * Temperature Range: -25 to 70C (-13 to 158F) * Short Body Sensors * Economically priced * Connector options * Carries mark M18 Flush Mount Sensing Distance Cable or Connector Style Cat. No. Cable 9984-2000 M18 Non-Flush Mount 8mm (.31in.) Cable 9984-2200 5mm (.20 in.) 65 9984-2065 65 9984-2265 PNP NPN Normally Open Normally Closed Normally Open Normally Closed 9984-2100 9984-2165 9984-2300 9984-2365 Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Current Switching Frequency Hysterisis Temperature Drift Repeatability Front Cap Material 10% 18V - 30V 10 mA 120 mA 1.5V 10 A 1000Hz 15% 10% .50mm (.02 in.) PBTP 10% 18V - 30V 10 mA 120 mA 1.5V 10 A 1000Hz 15% 10% .50mm (.02 in.) PBTP 10% 18V - 30V 10 mA 120 mA 1.5V 10 A 500Hz 15% 10% .80mm (.031in.) PBTP 10% 18V - 30V 10 mA 120 mA 1.5V 10 A 500Hz 15% 10% .80mm (.031 in.) PBTP M 18 M Fixed Cable PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.) cable length, change the last two digits of the part number to 02. For other cable lengths and/or PUR cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. 18 x 1 x 1 LED LED 35 35 M M 18 x 18 a 1 LED LED 65 Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. 3 40 50 0 18 (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 50 3 40 0 8 1 M M 12 x 1 12 PREVIOUS HOME NEXT FIND IT Accessories Metric/in. Conversion Table 1.5 mm 2.0 mm 4.0 mm 5.0 mm 6.0 mm 8.0 mm 10.0 mm 12.0 mm 15.0 mm 18.0 mm = = = = = = = = = = .06 in. .08 in. .16 in .20 in. .23 in. .31 in. .39 in. .47 in. .59 in. .70 in. 23.0 mm 28.0 mm 30.0 mm 32.0 mm 34.0 mm 40.0 mm 50.0 mm 51.0 mm 60.0 mm 80.0 mm = = = = = = = = = = .91 in. 1.10 in 1.18 in. 1.26 in. 1.38 in. 1.57 in. 1.97 in. 2.01 in. 2.36 in. 3.12 in. 2 meter (6 ft. 6 in.) DC Cable Assemblies for Quick Disconnect Sensors This table converts millimeters to inches in reference to the illustrations included on these pages 65 Connector 65 Connector 65 Connector 65 Connector 8000-5110 8000-5120 8000-5150 8000-5160 PVC, Straight PVC, Right Angle PVC, Right Angle, 2LED, NPN PVC, Right Angle, 2LED, PNP Change last digit of connector number to 5 for 5 meter cable Refer to pages 116-121 for more cable information M30 Flush Mount 10mm (.39 in.) Cable 9986-2000 M30 Non-Flush Mount 15mm (.59 in.) Cable 9986-2200 65 9986-2065 65 9986-2265 Mounting Brackets - see Pages 114-115 9986-2100 9986-2165 9986-2300 9986 -2365 10% 18V - 30V 10 mA 120 mA 1.5V 10 A 500Hz 15% 10% 1.0mm (.039 in.) PBTP 10% 18V - 30V 10 mA 120 mA 1.5V 10 A 500Hz 15% 10% 1.0mm (.039 in.) PBTP 10% 18V - 30V 10 mA 120 mA 1.5V 10 A 300Hz 15% 10% 1.5mm (.059 in.) PBTP 10% 18V - 30V 10 mA 120 mA 1.5V 10 A 300Hz 15% 10% 1.5mm (.059 in.) PBTP Note: Sensor dimensions in mm. Wiring Diagrams Note: Wire colors are applicable on cables purchased from Altech M M 30 x 1 30 x 1. 5 LED LED PNP Fixed Cable BR NPN Fixed Cable + BR * + LOAD 12 BK LOAD BK BL 35 BL *- - 23 Normally Open Normally Open M M 30 LED 30 x 1. x LED 5 12 1. 5 M 12 65 Connector BR + 1 65 Connector BR 1 * + LOAD 4 BK LOAD 4 BK 2 3 * BL - 2 3 BL - 3 40 0 18 (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 50 50 40 M 12 x 1 x 1 Normally Open Normally Open 19 PREVIOUS DC - 3 WIRE - GL SERIES Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-60V DC, 400mA, 2 LED's for Operating Voltage and Output Energized HOME NEXT FIND IT * Higher Current Output * Higher Voltage Range * Carries mark * IEC (529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection * Short Circuit Protection * Overload Protection * Reverse Polarity Protection * Wire Break Resistance * Temperature Range: -25 to 70C (-13 to 158F) M12 Flush Mount Sensing Distance Cable or Connector Style Cat. No. Cable 9982-4000 9982-4400 9982-4100 9982-4500 10% 10V - 60V 10 mA 400 mA 2.4V 10 A 2000Hz 15% 10% .20mm (.008 in.) PBTP M12 Non-Flush Mount 4mm (.16 in.) 65 Cable 9982-4200 9982-4600 9982-4300 9982-4700 10% 10V - 60V 10 mA 400 mA 2.4V 10 A 1000Hz 15% 10% .40mm (.016 in.) PBTP 2mm (.08 in.) 64 9982-4064 9982-4464 9982-4164 9982-4564 10% 10V - 60V 10 mA 400 mA 2.4V 10 A 2000Hz 15% 10% .20mm (.008 in.) PBTP 9982-4065 9982-4465 9982-4165 9982-4565 10% 10V - 60V 10 mA 400 mA 2.4V 10 A 2000Hz 15% 10% .20mm (.008 in.) PBTP 64 9984-4264 9982-4664 9982-4364 9982-4764 10% 10V - 60V 10 mA 400 mA 2.4V 10 A 1000Hz 15% 10% .40mm (.016 in.) PBTP 65 9982-4265 9982-4665 9982-4365 9982-4765 10% 10V - 60V 10 mA 400 mA 2.4V 10 A 1000Hz 15% 10% .40mm (.016 in.) PBTP PNP NPN Normally Open Normally Closed Normally Open Normally Closed Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Current Switching Frequency Hysterisis Temperature Drift Repeatability Front Cap Material Fixed Cable PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.) cable length, change the last two digits of the part number to 02. For other cable lengths and/or PUR cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. M M 12 x 1 2 LED 12 x 1 2 LED 45 35 45 M 12 12 x 1 2 LED 29 x 1 2 LED 2 LED 5 35 60 0 2 LED 5 35 60 0 20 (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 2 59 60 0 65 Style Connectors 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. 6 60 M 12 x 1 2 50 9 1 64 Style Connector 3-pin, Pico style, 8mm (.31 in.) supplied with Brass, Nickel Plated (BN) locknuts. M 8 x 1 6 M 8 x M 12 x 1 6 M PREVIOUS HOME NEXT FIND IT Accessories 2 meter (6 ft. 6 in.) DC Cable Assemblies for Quick Disconnect Sensors Metric/in. Conversion Table 1.0 mm = .04 in. 6.0 mm = .23 in. 8.0 mm = .31 in. 12.0 mm = .47 in. 18.0 mm = .70 in. .27.0 mm =1.06 in. 29.0 mm 35.0 mm 45.0 mm 50.0 mm 60.0 mm 80.0 mm = = = = = = 1.14 in 1.37 in. 1.77 in. 1.97 in. 2.36 in. 3.15 in. This table converts millimeters to inches in reference to the illustrations included on these pages 64 Connector 64 Connector 64 Connector 8000-5220 PVC, Straight 8000-5230 PVC, Right Angle, 2LED, PNP 8000-5240 PVC, Right Angle, 2LED, NPN M18 Flush Mount 5mm (.20 in.) Cable 9984-4000 9984-4400 9984-4100 9984-4500 10% 10V - 60V 10 mA 400 mA 2.4V 10 A 1000Hz 15% 10% .25mm (.01 in.) PBTP M18 Non-Flush Mount 8mm (.31 in.) Cable 9984-4200 9984-4600 9984-4300 9984-4700 10% 10V - 60V 10 mA 400 mA 2.4V 10 A 500Hz 15% 10% .40mm (.016 in.) PBTP 65 Connectors, 4 PIN - 3 Wire cable (PIN 1, 3, 4 ) : 65 Connector 8000-5110 PVC, Straight 65 Connector 8000-5120 PVC, Right Angle 65 Connector 8000-5150 PVC, Right Angle, 2LED, NPN 65 Connector 8000-5160 PVC, Right Angle, 2LED, PNP 65 Connectors, 4 PIN - 4 Wire cable (PIN 1, 2, 3, 4) : 65 Connector 8000-5280 PVC Right Angle Change last digit of connector number to 5 for 5 meter cable Refer to pages 116-121 for more cable information 65 9984-4065 9984-4465 9984-4165 9984-4565 10% 10V - 60V 10 mA 400 mA 2.4V 10 A 1000Hz 15% 10% .25mm (.01 in.) PBTP 65 9984-4265 9984-4665 9984-4365 9984-4765 10% 10V - 60V 10 mA 400 mA 2.4V 10 A 500Hz 15% 10% .40mm (.016 in.) PBTP Mounting Brackets - see Pages 114-115 Wiring Diagrams Note: Wire colors are applicable on cables purchased from Altech PNP Fixed Cable BR BK LOAD BL NPN Fixed Cable + BR * + LOAD BK BL *- - Normally Open Normally Open Fixed Cable BR BK LOAD BL Fixed Cable + BR * + LOAD BK BL * - - Normally Closed Normally Closed Note: Sensor dimensions in mm. 64 Connector 1 BR + 2/4 3 BK 2/4 LOAD BL * - BK BL - 64 Connector 1 BR M 18 x 1 2 LED M 18 x 1 *+ LOAD 2 LED 8 3 3 45 5 45 27 Normally Open Normally Open 64 Connector 1 BR BK 2/4 3 LOAD BL* - + 64 Connector 1 BR BK BL 3 - *+ LOAD 2/4 Normally Closed Normally Closed 65 Connector BR + 1 65 Connector BR 1 * + LOAD 4 BK LOAD 4 BK 2 3 * BL - 2 3 BL - Normally Open M 18 x 1 Normally Open M 18 x 1 2 LED 2 LED 1 65 Connector BR + 1 BL - LOAD 65 Connector BR * + LOAD BL - 4 * 4 50 35 2 50 7 8 2 3 WHT 2 3 WHT 60 60 Normally Closed Normally Closed (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 21 PREVIOUS DC - 3 WIRE - GL SERIES Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-60V DC, 400mA 2 LED's for Operating Voltage and Output Energized HOME NEXT FIND IT * IEC (529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection * Short Circuit Protection * Overload Protection * Reverse Polarity Protection * Wire Break Resistance * Temperature Range: -25 to 70C (-13 to 158F) * Higher Current Output * Higher Voltage Range * Carries mark M30 Flush Mount Sensing Distance Cable or Connector Style Cat. No. Cable 9986-4000 9986-4400 9986-4100 9986-4500 10% 10V-60V 10 mA 400 mA 2.4V 10 A 500 Hz 15% 10% M30 Non-Flush Mount 15mm (.59 in.) Cable 9986-4200 9986-4600 9986-4300 9986-4700 10% 10V - 60V 10 mA 400 mA 2.4V 10 A 300 Hz 15% 10% .75mm (.030 in.) PBTB 10mm (.39 in.) 65 9986-4065 9986-4465 9986-4165 9986-4565 10% 10V - 60V 10 mA 400 mA 2.4V 10 A 500 Hz 15% 10% .50mm (.020 in.) PBTP 65 9986-4265 9986-4665 9986-4365 9986-4765 10% 10V - 60V 10 mA 400 mA 2.4V 10 A 300 Hz 15% 10% .75mm (.030 in.) PBTB PNP NPN Normally Open Normally Closed Normally Open Normally Closed Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Cap Material .50mm (.020 in.) PBTP Note: Sensor dimensions in mm. M M 30 x 30 x 3 45 5 Fixed Cable PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.) cable length, change the last two digits of the part number to 02. For other cable lengths and/or PUR cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. 1, 1, 5 5 2 LED 2 LED 23 45 M 30 x 1, 5 5 2 LED 65 Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. 2 LED 50 35 60 22 (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 60 50 23 12 12 M 30 x 1, PREVIOUS Accessories 2 meter (6 ft. 6 in.) DC Cable Assemblies for Quick Disconnect Sensors 65 Connectors, 4 PIN - 3 Wire cable (PIN 1, 3, 4) : 65 Connector 8000-5110 PVC, Straight 65 Connector 8000-5120 PVC, Right Angle 65 Connector 8000-5150 PVC, Right Angle, 2LED, NPN 65 Connector 8000-5160 PVC, Right Angle, 2LED, PNP 65 Connectors, 4PIN - 4 Wire cable (PIN 1, 2, 3, 4) : 65 Connectors 8000-5280 PVC, Right Angle HOME NEXT FIND IT Metric/in. Conversion Table 1.5 mm 12.0 mm 23.0 mm 35.0 mm = .06 in. = .47 in. = .90 in. = 1.37 in. 45.0 mm = 1.77 in. 50.0 mm = 1.96 in. 60.0 mm = 2.36 in. This table converts millimeters to inches in reference to the illustrations included on these pages Change last digit of connector number to 5 for 5 meter cable Refer to pages 116-121 for more cable information Mounting Brackets - see Pages 114-115 Wiring Diagrams Note: Wire colors are applicable on cable purchased from Altech PNP Fixed Cable BR BK LOAD BL NPN Fixed Cable + BR * + LOAD BK BL *- - Normally Open Normally Open Fixed Cable BR BK LOAD BL Fixed Cable + BR * + LOAD BK BL * - - Normally Closed Normally Closed 65 Connector BR + 1 65 Connector BR 1 * + LOAD 4 BK LOAD 4 BK 2 3 * BL - 2 3 BL - Normally Open Normally Open 65 Connector BR 1 + 1 BL *- LOAD 65 Connector BR * + LOAD BL - 4 4 2 3 WHT 2 3 WHT Normally Closed Normally Closed (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 23 PREVIOUS DC - 3 WIRE STANDARD Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V DC, 200 mA, 1 LED for Output Energized HOME NEXT FIND IT * IEC (529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection * Short Circuit Protection * Overload Protection * Reverse Polarity Protection * Wire Break Resistance * Temperature Range: -25 to 70C (-13 to 158F) * Most complete range of Fixed Cable and Quick Disconnect Styles * Available in normally open (N.O.) and normally closed (N.C.) output configuration * Industry standard 10-30V DC operating voltage and 200mA output current * Carries mark M8 Flush Mount Sensing Distance Cable or Connector Style Cat. No. Cable 9961-0200 9961-4400 9961-0300 9961-4500 10% 10V-30V 10 mA 200 mA 2.4V 10 A 2000 Hz 15% 10% .15mm (.006 in.) PBTP 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 2000 Hz 15% 10% 9961-0363 M8 Non-Flush Mount 2mm (.08 in.) 65 9961-0265 9961-4465 9961-0365 9961-4565 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 2000 Hz 15% 10% 1.5mm (.06 in.) 63 9961-0263 64 9961-0264 9961-4464 9961-0364 9961-4564 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 2000 Hz 15% 10% Cable 9961-0400 9961-4600 9961-0500 9961-4700 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 2000 Hz 15% 10% .20mm (.008in.) PBTB 63 9961-0463 64 9961-0464 9961-4664 65 9961-0465 9961-4665 9961-0565 9961-4765 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 2000 Hz 15% 10% .20mm (.008in.) PBTB PNP NPN Normally Open Normally Closed Normally Open Normally Closed 9961-0563 9961-0564 9961-4764 Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Cap Material 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 2000 Hz 15% 10% 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 2000 Hz 15% 10% .15mm (.006 in.) .15mm (.006 in.) .15mm (.006in.) PBTP PBTP PBTP .20mm (.008in.) .20mm (.008in.) PBTB PBTB Fixed Cable PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.) cable length, change the last two digits of the part number to 02. For other cable lengths and/or PUR cable, please consult Altech. Non-metallic locknuts for M8 and Brass, Nickel Plated (BN) locknuts for M12 through M30. M M 8 x 1 LED 8 x 1 LED 40 35 43 M 8 x 1 4 PORT LED 43 5 M 8 x 1 4 PORT LED 64 Style Connector 3-pin, Pico style, 8mm (.31 in.) supplied with non-metallic locknuts for M8 and Brass, Nickel Plated (BN) locknuts for M12 through M30. 50 34 LED (65 CN) 50 1 M 8 x 1 50 1 23 5 x LED (65 CN) LED (63 CN) 63 and 65 Style Connectors 4-pin, Micro style, 12mm (.47 in.) supplied with Non-metallic locknuts for M8 and Brass, Nickel Plated (BN) locknuts for M12 through M30. The 63 Connector is clear, offering 360 LED viewing. LED (63 CN) 28 50 24 (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 29 M 8 x M 8 x 1 M 12 5 M 8 x 1 M 12 x 1 PREVIOUS HOME NEXT FIND IT Accessories 2 meter (6 ft. 6 in.) DC Cable Assemblies for Quick Disconnect Sensors 64 Connector 8000-5220 PVC, Straight 64 Connector 8000-5230 PVC, Right Angle, 2LED, PNP 64 Connector 8000-5240 PVC, Right Angle, 2LED, NPN 63/65 Connectors, 4 PIN - 3 Wire cable (PIN 1, 3, 4) : 63/65 Connector 8000-5110 PVC, Straight 63/65 Connector 8000-5120 PVC, Right Angle 63/65 Connector 8000-5150 PVC, Right Angle, 2LED, NPN 63/65 Connector 8000-5160 PVC, Right Angle, 2LED, PNP 63/65 Connectors, 4PIN - 4 Wire cable (PIN 1, 2, 3, 4) : 63/65 Connectors 8000-5280 PVC, Right Angle Change last digit of connector number to 5 for 5 meter cable Refer to pages 116-121 for more cable information Metric/in. Conversion Table 1.0 mm 5.0 mm 6.0 mm 8.0 mm 12.0 mm 23.0 mm 28.0 mm = .04 in. = .20 in. = .23 in. = .31 in. = .47 in. = .90 in. =1.10 in. 29.0 mm 34.0 mm 35.0 mm 40.0 mm 43.0 mm 50.0 mm 60.0 mm = = = = = = = 1.14 in. 1.34 in. 1.37 in. 1.57 in. 1.69 in. 1.47 in. 2.36 in. This table converts millimeters to inches in reference to the illustrations included on these pages M12 Flush Mount 2mm (.08 in.) Cable 9962-4000 9962-4400 9962-4100 9962-4500 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 2000 Hz 15% 10% 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 2000 Hz 15% 10% 9962-4163 M12 Non-Flush Mount 4mm (.16 in.) 65 9962-4065 9962-4465 9962-4165 9962-4565 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 2000 Hz 15% 10% 63 9962-4063 64 9962-4064 9962-4464 9962-4164 9962-4564 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 2000 Hz 15% 10% Cable 9962-4200 9962-4600 9962-4300 9962-4700 10% 10V - 30V 10 mA 200 mA 2.4V 10A 1000 Hz 15% 10% 63 9962-4263 64 9962-4264 9962-4664 65 9962-4265 9962-4665 9962-4365 9962-4765 10% 10V - 30V 10 mA 200 mA 2.4V 10A 1000 Hz 15% 10% Mounting Brackets - see Pages 114-115 Wiring Diagrams Note: Wire colors are applicable to cable purchased from Altech 9961-4363 9962-4364 9962-4764 10% 10V - 30V 10 mA 200 mA 2.4V 10A 1000 Hz 15% 10% 10% 10V - 30V 10 mA 200 mA 2.4V 10A 1000 Hz 15% 10% PNP Fixed Cable BR BK LOAD NPN Fixed Cable + BR * + LOAD BK BL * BL - Normally Open - Normally Open Fixed Cable BR BK LOAD Fixed Cable + BR * + .20mm (.008in.) .20mm (.008in.) .20mm (.008in.) .20mm (.008in.) PBTB PBTB PBTB PBTB .40mm (.016in.) .40mm (.016in.) .40mm (.016in.) .40mm (.016in.) PBTB PBTB PBTB PBTB LOAD BK BL BL * - - Note: Sensor dimensions in mm. Normally Closed Normally Closed 64 Connector 1 BR BK 2/4 LOAD BL * - + 64 Connector 1 BR BK BL 3 - M M 12 x 1 LED 12 x 1 *+ LOAD LED 2/4 6 3 40 Normally Open Normally Open 34 64 Connector 1 BR BK 2/4 3 LOAD BL* - + 64 Connector 1 BR BK BL 3 - *+ LOAD M 12 x M 12 x 2/4 4 PORT LED 4 PORT LED 4 50 0 34 6 50 1 1 Normally Closed Normally Closed 63/65 Connector BR + 1 63/65 Connector BR 1 60 60 LED (63 CN) 6 4 50 0 34 50 60 60 M 8 (c)Altech M 8 * + LOAD x 1 LED (65 CN) x 1 4 BK LOAD 4 BK 2 3 * BL - 2 3 BL - LED (65 CN) Normally Open Normally Open M Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 M 12 x 1 12 x 1 63/65 Connector BR 1 + 1 BK - LOAD LED (63 CN) 65 Connector BR * + LOAD BL - 4 * 4 2 3 WHT 2 3 WHT Normally Closed Normally Closed 25 PREVIOUS DC - 3 WIRE - STANDARD Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V DC, 200mA, 1 LED for Output Energized HOME NEXT FIND IT * IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection * Short Circuit Protection * Overload Protection * Reverse Polarity Protection * Wire Break Resistance * Temperature Range: -25 to 70C (-13 to 158F) * Most complete range of Fixed Cable and Quick Disconnect Styles * Available in normally open (N.O.) and normally closed (N.C.) output configuration * Industry standard 10-30V DC operating voltage and 200mA output current * Carries mark M18 Flush Mount Sensing Distance Cable or Connector Style Cat. No. Cable 9964-4000 9964-4400 9964-4100 9964-4500 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 1000 Hz 15% 10% .25mm (.01 in.) PBTP 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 1000 Hz 15% 10% .25mm (.01 in.) PBTP 9964-4163 M18 Non-Flush Mount 8mm (.31 in.) 65 9964-4065 9964-4465 9964-4165 9964-4565 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 1000 Hz 15% 10% 5mm (.20 in.) 63 9964-4063 Cable 9964-4200 9964-4600 9964-4300 9964-4700 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 500 Hz 15% 10% .40mm (.016 in.) PBTB 63 9964-4263 65 9964-4265 9964-4665 PNP NPN Normally Open Normally Closed Normally Open Normally Closed 9964-4363 9964-4365 9964-4765 Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Cap Material 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 500 Hz 15% 10% .40mm (.016 in.) PBTB 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 500 Hz 15% 10% .40mm (.016 in.) PBTB .25mm (.01 in.) PBTP M M 18 Fixed Cable PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.) cable length, change the last two digits of the part number to 02. For other cable lengths and/or PUR cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. 18 x 1 LED x 1 LED 40 32 LED (65 CN) LED (65 CN) x 1 40 M 18 x 1 5 60 1 8 4 50 60 1 63 and 65 Style Connectors 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts.The 63 Connector is clear, offering 360 LED viewing. LED (63 CN) LED (63 CN) 26 (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 32 M 12 x 1 8 M 18 M 12 x 1 PREVIOUS HOME NEXT FIND IT Accessories Metric/in. Conversion Table 1.5 mm 2.0 mm 4.0 mm 5.0 mm 6.0 mm 8.0 mm 10.0 mm 12.0 mm 15.0 mm 18.0 mm = = = = = = = = = = .06 in. .08 in. .16 in .20 in. .23 in. .31 in. .39 in. .47 in. .59 in. .70 in. 23.0 mm 28.0 mm 30.0 mm 32.0 mm 34.0 mm 40.0 mm 50.0 mm 51.0 mm 60.0 mm 80.0 mm = = = = = = = = = = .91 in. 1.10 in 1.18 in. 1.26 in. 1.34 in. 1.57 in. 1.97 in. 2.01 in. 2.36 in. 3.12 in. 2 meter (6 ft. 6 in.) DC Cable Assemblies for Quick Disconnect Sensors This table converts millimeters to inches in reference to the illustrations included on these pages 63/65 Connectors, 4 PIN - 3 Wire cable (PIN 1, 3, 4) : 63/65 Connector 8000-5110 PVC, Straight 63/65 Connector 8000-5120 PVC, Right Angle 63/65 Connector 8000-5150 PVC, Right Angle, 2LED, NPN 63/65 Connector 8000-5160 PVC, Right Angle, 2LED, PNP 63/65 Connectors, 4PIN - 4 Wire cable (PIN 1, 2, 3, 4) : 63/65 Connectors 8000-5280 PVC, Right Angle Change last digit of connector number to 5 for 5 meter cable M30 Flush Mount 10mm (.39 in.) Cable 9966-4000 9966-4400 9966-4100 9966-4500 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 500 Hz 15% 10% .50mm (.02 in.) PBTB 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 500 Hz 15% 10% .50mm (.02 in.) PBTB 9966-4163 M30 Non-Flush Mount 15mm (.59 in.) 65 Cable 9966-4200 9966-4600 9966-4300 9966- 4700 10% 10V - 30V 10 mA 200 mA 2.4V 10A 300 Hz 15% 10% .75mm (.03 in.) PBTB 10% 10V - 30V 10 mA 200 mA 2.4V 10A 300 Hz 15% 10% .75mm (.03 in.) PBTB Refer to pages 116-121 for more cable information 63 9966-4063 63 9966-4263 65 9966-4265 9966-4665 9966-4365 9966-4765 10% 10V - 30V 10 mA 200 mA 2.4V 10A 300 Hz 15% 10% .75mm (.03 in.) PBTB 9966-4065 9966-4465 9966-4165 9966-4565 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 500 Hz 15% 10% .50mm (.02 in.) PBTB Mounting Brackets - see Pages 114-115 Wiring Diagrams Note: Wire colors are applicable to cable purchased from Altech Note: Sensor dimensions in mm. PNP Fixed Cable BR NPN Fixed Cable + BR * + LOAD M M 30 x 1, 5 LED BK LOAD BK BL 30 x 1, 5 LED * BL - Normally Open - Normally Open 12 Fixed Cable BR Fixed Cable + BR 40 28 40 * + BK LOAD BL BK BL LOAD * - - Normally Closed Normally Closed 63/65 Connector BR + 63/65 Connector BR 1 LED (65 CN) LED (65 CN) * + LOAD 1 4 BK LOAD 4 BK M M 30 x 1, 5 30 x 1, 5 * LED (63 CN) LED (63 CN) 2 3 BL - 2 3 BL - Normally Open Normally Open 12 63/65 Connector BR 1 + 1 BL - LOAD 63/65 Connector BR 4 50 60 1 28 * + LOAD BL - M 5 60 1 M (c)Altech 12 12 x 1 Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 x 1 4 * 4 2 3 WHT 2 3 WHT Normally Closed Normally Closed 27 PREVIOUS DC - 3 WIRE - EXTENDED SENSING DISTANCE Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V DC, 200mA 1 LED for Output Energized HOME NEXT FIND IT * IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection * Short Circuit Protection * Overload Protection * Reverse Polarity Protection * Wire Break Resistance * Temperature Range: -25 to 70C (-13 to 158F) * Up to 2 times sensing distance over standard sensors * Reduces accidental collisions * Ideal for applications where larger sensing distance is required but mounting space is tight * Carries mark M8 Flush Mount Sensing Distance Cable or Connector Style Cat. No. Cable 9981-4000 M8 Non-Flush Mount 3mm (.12 in.) 65 Cable 9981-4200 2mm (.08 in.) 64 9981-4064 9981-4065 64 9981-4264 65 9981-4265 PNP NPN Normally Open Normally Closed Normally Open Normally Closed 9981-4100 9981-4164 9981-4165 9981-4300 9981-4364 9981-4365 Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Cap Material 10% 10V-30V 12 mA 200 mA 2.4V 10 A 2000 Hz 15% 10% .2mm (.008 in.) PBTP 10% 10V - 30V 12 mA 200 mA 2.4V 10 A 2000 Hz 15% 10% .2mm (.008 in.) PBTP 10% 10V - 30V 12 mA 200 mA 2.4V 10 A 2000 Hz 15% 10% .2mm (.008 in.) PBTP 10% 10V - 30V 12 mA 200 mA 2.4V 10 A 2000 Hz 15% 10% .3mm (.012 in.) PBTB 10% 10V - 30V 12 mA 200 mA 2.4V 10 A 2000 Hz 15% 10% .3mm (.012 in.) PBTB 10% 10V - 30V 12 mA 200 mA 2.4V 10 A 2000 Hz 15% 10% .3mm (.012 in.) PBTB M M Fixed Cable PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.) cable length, change the last two digits of the part number to 02. For other cable lengths and/or PUR cable, please consult Altech. Non-metallic locknuts for M8 and Brass, Nickel Plated (BN) locknuts for M12 through M30. 8 8 x 1 LED x 1 35 35 M 8 8 5 x 1 2 50 9 LED LED M x 1 64 Style Connector 3-pin, Pico style, 8mm (.31 in.) supplied with non-metallic locknuts for M8 and Brass, Nickel Plated (BN) locknuts for M12 through M30. LED LED 50 34 LED 50/65 Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Non-Metallic locknuts for M8 and Brass, Nickel Plated (BN) locknuts for M12 through M30. 28 50 28 (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 50 1 23 M 12 x 5 M 12 x 1 5 M 8 x 1 M 8 x 1 M 8 x 1 M 8 x 1 PREVIOUS HOME NEXT FIND IT Accessories 2 meter (6 ft. 6 in.) DC Cable Assemblies for Quick Disconnect Sensors Metric/in. Conversion Table 1.0 mm 5.0 mm 8.0 mm 12.0 mm 23.0 mm 27.0 mm 28.0 mm = .04 in. = .20 in. = .31 in. = .47 in. = .90 in. =1.06 in. =1.10 in. 29.0 mm 30.0 mm 34.0 mm 35.0 mm 40.0 mm 50.0 mm = = = = = = 1.14 in. 1.18 in. 1.33 in. 1.37 in. 1.57 in. 1.96 in. This table converts millimeters to inches in reference to the illustrations included on these pages 64 Connector 64 Connector 64 Connector 8000-5220 PVC, Straight 8000-5230 PVC, Right Angle, 2LED, PNP 8000-5240 PVC, Right Angle, 2LED, NPN PVC, Straight PVC, Right Angle PVC, Right Angle, 2LED, NPN PVC, Right Angle, 2LED, PNP 50/65 Connector 8000-5110 50/65 Connector 8000-5120 50/65 Connector 8000-5150 50/65 Connector 8000-5160 M12 Flush Mount 4mm (.16 in.) Cable 9982-4900 M18 Flush Mount 8mm (.31 in.) Cable 9984-4900 Change last digit of connector number to 5 for 5 meter cable Refer to pages 116-121 for more cable information 65 9982-4950 65 9984-4950 Mounting Brackets - see Pages 114-115 10% 10V - 30V 12mA 200 mA 2.4V 10 A 1500 Hz 15% 10% .40mm (.016 in.) PBTB 10% 10V - 30V 12 mA 200 mA 2.4V 10 A 1500 Hz 15% 10% .40mm (.016 in.) PBTB 10% 10V - 30V 12 mA 200 mA 2.4V 10A 500 Hz 15% 10% .80mm (.03 in.) PBTB 10% 10V - 30V 12 mA 200 mA 2.4V 10A 500 Hz 15% 10% .80mm (.03in.) PBTB Wiring Diagrams Note: Wire colors are applicable to cable purchased from Altech Note: Sensor dimensions in mm. PNP Fixed Cable BR BK LOAD BL NPN Fixed Cable + BR * + LOAD BK BL *- - Normally Open Normally Open 64 Connector 1 BR BK 2/4 3 BL * - LOAD + 64 Connector 1 BR BK BL 3 - *+ LOAD 2/4 Normally Open Normally Open 50/65 Connector BR + 1 50/65 Connector BR 1 * + LOAD 4 BK LOAD 4 BK 2 3 * BL - 2 3 BL - Normally Open Normally Open (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 29 PREVIOUS DC - 3 WIRE - EXTENDED SENSING DISTANCE Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V DC, 200mA 1 LED for Ouput Energized HOME NEXT FIND IT * IEC (529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection * Short Circuit Protection * Overload Protection * Reverse Polarity Protection * Wire Break Resistance * Temperature Range: -25 to 70C (-13 to 158F) * Up to 2 times sensing distance over standard sensors * Reduces accidental collisions * Ideal for applications where larger sensing distance is required but mounting space is tight * Carries mark M30 Flush Mount Sensing Distance Cable or Connector Style Cat. No. Cable 9966-3900 Metric/in. Conversion Table 1.5 mm 30.0 mm 50.0 mm 60.0 mm 80.0 mm = = = = = .06 in. 1.20 in. 1.47 in. 2.36 in. 3.12 in. 15mm (.59 in.) 65 9966-3965 PNP NPN Normally Open Normally Closed Normally Open Normally Closed This table converts millimeters to inches in reference to the illustrations included on these pages Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Cap Material 10% 10V-30V 12 mA 200 mA 2.4V 10 A 200 Hz 15% 10% 1.5mm (.06 in.) PBTP 10% 10V - 30V 12 mA 200 mA 2.4V 10 A 200 Hz 15% 10% 1.5mm (.06 in.) PBTP Accessories 2 meter (6 ft. 6 in.) DC Cable Assemblies for Quick Disconnect Sensors 65 Connector 8000-5110 PVC, Straight 65 Connector 8000-5120 PVC, Right Angle 65 Connector 8000-5150 PVC, Right Angle, 2LED, NPN 65 Connector 8000-5160 PVC, Right Angle, 2LED, PNP Change last digit of connector number to 5 for 5 meter cable Refer to pages 116-121 for more cable information Mounting Brackets - see Pages 114-115 Note: Sensor dimensions in mm. Wiring Diagrams Note: Wire colors are applicable to cable purchased from Altech M Fixed Cable PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.) cable length, change the last two digits of the part number to 02. For other cable lengths and/or PUR cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. 30 x 1, 5 PNP Fixed Cable BR BK LOAD LED + 5 60 0 BL *- Normally Open M 30 x 1, 5 65 Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. LED 1 65 Connector BR + 4 BK LOAD 2 3 * BL - 60 Normally Open 30 (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 80 PREVIOUS DC - 3 WIRE HIGH SPEED Brass, Nickel Plated (BN), Cylindrial,Threaded, 10-30V DC, 200mA 1 LED for Output Energized HOME NEXT FIND IT * IEC (529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection * Short Circuit Protection * Overload Protection * Reverse Polarity Protection * Wire Break Resistance * Temperature Range: -25 to 70C (-13 to 158F) Metric/in. Conversion Table 1.0 mm 12 mm 40.0 mm 45.0 mm 50.0 mm 65.0 mm = = = = = = .04 in. .47 in. 1.57 in. 1.77 in. 1.96 in. 2.55 in. * Switching frequency of 4000 Hz * Standard body length * Carries mark M12 Flush Mount Sensing Distance Cable or Connector Style Cat.No. Cable 9962-2300 2mm (.08 in.) 65 9962-2365 PNP Normally Open This table converts millimeters to inches in reference to the illustrations included on these pages Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Cap Material 10% 10V-30V 10 mA 200 mA 2.4V 10 A 4000 Hz to DIN 500 10 15% 10% .20mm (.008 in.) PBTP 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 4000 Hz to DIN 500 10 15% 10% .20mm (.008 in.) PBTP Accessories 2 meter (6 ft. 6 in.) DC Cable Assemblies for Quick Disconnect Sensors 65 Connector 8000-5110 PVC, Straight 65 Connector 8000-5120 PVC, Right Angle 65 Connector 8000-5150 PVC, Right Angle, 2LED, NPN 65 Connector 8000-5160 PVC, Right Angle, 2LED, PNP Change last digit of connector number to 5 for 5 meter cable Refer to pages 116-121 for more cable information Mounting Brackets - see Pages 114-115 Note: Sensor dimensions in mm. Wiring Diagrams Note: Wire colors are applicable to cable purchased from Altech M 12 Fixed Cable PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.) cable length, change the last two digits of the part number to 02. For other cable lengths and/or PUR cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. x 1 LED PNP 40 Fixed Cable BR + 50 BK LOAD BL *- Normally Open M 12 x 1 65 Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. LED 65 Connector 45 BR + 1 4 BK LOAD 65 2 3 * BL - Normally Open (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 31 PREVIOUS DC - 3 WIRE - PLASTIC & METAL HOUSING - Brass, Nickel Plated (BN), and Plastic (TROGAMID T) Cylindrical,Threaded, 10-30V DC, 400mA 1 LED for Output Energized HOME NEXT FIND IT * IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection * Short Circuit Protection * Overload Protection * Reverse Polarity Protection * Wire Break Resistance * Temperature Range: -25 to 70C (-13 to 158F) * Metal and plastic housings * Higher output currents, 400mA * Long body length * Carries mark M12 Flush Mount Sensing Distance Cable or Connector Cat. No. M12 Non-Flush Mount 4mm (.16 in.) Cable 9962-3300 9962-1600 M18 Flush Mount 5mm (.20 in.) Cable 9964-3100 9964-1500 2mm (.08 in.) Cable 9962-3100 9962-1400 PNP NPN Normally Open Normally Closed Normally Open Normally Closed 9962-3200 9962-1500 9962-3400 9962-1700 9964-3200 9964-1600 Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Current Switching Frequency Hysterisis Temperature Drift Repeatability Front Cap Material Housing Material 10% 10-30V 10 mA 400 mA 2.4V 10 A 2000Hz 15% 10% .20mm (.008 in.) PBTB Trogamid T 10% 10-30V 10 mA 400 mA 2.4V 10 A 2000Hz 15% 10% .20mm (.008 in.) PBTB Nickel Plated Brass 10% 10-30V 10 mA 400 mA 2.4V 10 A 1000Hz 15% 10% .40mm (.016 in.) PBTB Trogamid T 10% 10-30V 10 mA 400 mA 2.4V 10 A 1000Hz 15% 10% .40mm (.016 in.) PBTB Nickel Plated Brass 10% 10-30V 10 mA 400 mA 2.4V 10 mA 1000Hz 15% 10% .5mm (.02 in.) PBTB Trogamid T 10% 10-30V 10 mA 400 mA 2.4V 10mA 1000Hz 15% 10% .5mm (.02 in.) PBTB Nickel Plated Brass Fixed Cable PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.) cable length, change the last two digits of the part number to 02. For other cable lengths and/or PUR cable, please consult Altech. Supplied with non-metallic locknuts for Trogamid T housings, and Brass, Nickel Plated (BN) locknuts for Nickel Plated Brass housings. M 12 x 1 M M 12 x 1 18 x 1 LED LED LED 6 50 32 (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 50 5 60 0 40 34 PREVIOUS HOME NEXT FIND IT Accessories Metric/in. Conversion Table 1 mm 1.5 mm 6.0 mm 8.0 mm 12.0 mm 18.0 mm 30.0 mm = .04 in. = .06 in. = .23 in. = .31 in. = .47 in. = .70 in. =1.20 in. 34.0 mm 38.0 mm 40.0 mm 42.0 mm 50.0 mm 60.0 mm = = = = = = 1.31 in. 1.50 in. 1.57 in. 1.65 in. 1.97 in. 2.36 in. This table converts millimeters to inches in reference to the illustrations included on these pages Mounting Brackets - see Pages 114-115 M18 Non-Flush Mount M30 Flush Mount 8mm (.31 in.) Cable 9964-3300 9964-1700 9966-3100 M30 Non-Flush Mount 15mm (.59 in.) Cable 9966-3300 9966-1300 10mm (.39 in.) Cable 9966-1100 9964-3400 9964-1800 9966-3200 9966-1200 9966-3400 9966-1400 10% 10-30V 10 mA 400 mA 2.4V 10mA 500Hz 15% 10% .8mm (.03 in.) PBTB Trogamid T 10% 10-30V 10 mA 400 mA 2.4V 10mA 500Hz 15% 10% .8mm (.03 in.) PBTB Nickel Plated Brass 10% 10-30V 10 mA 400 mA 2.4V 10mA 500Hz 15% 10% 1.0mm (.04 in) PBTB Trogamid T 10% 10-30V 10 mA 400 mA 2.4V 10mA 500Hz 15% 10% 1.0mm (.04 in) PBTB Nickel Plated Brass 10% 10-30V 10 mA 400 mA 2.4V 10mA 300Hz 15% 10% 1.5mm (.06 in) PBTB Trogamid T 10% 10-30V 10 mA 400 mA 2.4V 10mA 300Hz 15% 10% 1.5mm (.06 in) PBTB Nickel Plated Brass Note: Sensor dimensions in mm. Wiring Diagrams Note: Wire colors are applicable to cable purchased from Altech PNP M 18 x 1 M 30 x 1, 5 M 30 x 5 1, NPN Fixed Cable + BR BR BK LOAD BK BL Fixed Cable * + LOAD LED LED 42 8 LED 12 5 60 0 BL 60 38 *- 60 - Normally Open Normally Open (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 33 PREVIOUS DC - 3 WIRE MINI METAL HOUSING Cylindrical, 10-30V DC, 200mA LED for Output Energized HOME NEXT FIND IT * IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection * Short Circuit Protection * Overload Protection * Reverse Polarity Protection * Wire Break Resistance * Temperature Range: -25 to 70C (-13 to 158F) * 4mm, 5mm, and 6.5mm diameter * Economically Priced * Non-connector models feature polyurethane (PUR) cables * Carries mark O 4 Flush Mount Sensing Distance Cable or Connector Style Cat. No. Cable 9980-1010 M5 Flush Mount 0.8mm (0.03 in.) Cable 9980-2010 0.8mm (0.03 in.) 64 9980-1064 64 9980-2064 PNP NPN Normally Open Normally Closed Normally Open Normally Closed 9980-1110 9980-1164 9980-2110 9980-2164 Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Cap Material Housing Material 10% 10V-30V 10 mA 200 mA 2V 100 A 5000 Hz Typ. 5% 10% 10% 10V - 30V 10 mA 200 mA 2V 100 A 5000 Hz Typ. 5% 10% .04mm (.003 in.) PBTP Nickel Plated Brass 10% 10V - 30V 10 mA 200 mA 2V 100 A 5000 Hz Typ. 5% 10% .04mm (.003in.) PBTB Nickel Plated Brass 10% 10V - 30V 10 mA 200 mA 2V 100 A 5000 Hz Typ. 5% 10% .04mm (.003in.) PBTB Nickel Plated Brass .04mm (.003 in.) PBTP Nickel Plated Brass M 5 18 25 LED 64 Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts for M5 model. LED 25 M O 5 4 x 5 0, 19 18 19 38 34 (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 38 23 M 8 x 1 18 M 8 x1 20 18 Fixed Cable PUR 2m (6 ft. 6 in.).Supplied with Brass, Nickel Plated (BN) locknuts for M5 model. LED LED x O 4 0, 5 PREVIOUS HOME NEXT FIND IT Accessories 2 meter (6 ft. 6 in.) DC Cable Assemblies for Quick Disconnect Sensors Metric/in. Conversion Table .5 mm = 1.0 mm = 3.5 mm = 4.0 mm = 5.0 mm = 6.5 mm = 8.0 mm = .019in. .04 in. .13 in .15 in. .19 in. .25 in. .31 in. 19.0 mm 20.0 mm 23.0 mm 25.0 mm 35.0 mm 40.0 mm 43.0 mm = .74 in. = .78 in = .90 in. = .94 in. = 1.37 in. = 1.57 in. = 1.69 in. This table converts millimeters to inches in reference to the illustrations included in this catalog 64 Connector 64 Connector 64 Connector 8000-5220 PVC, Straight 8000-5230 PVC, Right Angle, 2LED, PNP 8000-5240 PVC, Right Angle, 2LED, NPN Change last digit of connector number to 5 for 5 meter cable Refer to pages 116-121 for more cable information O 6.5 Flush Mount 1.5mm (0.06 in.) Cable 9961-1200 O 6.5 Non-Flush Mount 3.0mm (0.11 in.) Cable 9961-1300 65 9961-1264 65 9961-1364 Mounting Brackets - see Pages 114-115 10% 10V - 30V 8 mA 200 mA 2.4V 10 A 2000 Hz 15% 10% .15mm (.006in.) PBTB Stainless Steel 10% 10V - 30V 8 mA 200 mA 2.4V 10 A 2000 Hz 15% 10% .15mm (.006in.) PBTB Stainless Steel 10% 10V - 30V 8 mA 200 mA 2.4V 10 A 2000 Hz 15% 10% .15mm (.006in.) PBTB Stainless Steel 10% 10V - 30V 8 mA 200 mA 2.4V 10 A 2000 Hz 15% 10% .15mm (.006in.) PBTB Stainless Steel Note: Sensor dimensions in mm. Wiring Diagrams Note: Wire colors are applicable to cabl;e purchased from Altech PNP NPN Fixed Cable + BR BR BK LOAD BL BK BL O 6, 5 LED Fixed Cable LED 5 * + LOAD 35 40 *- 40 - Normally Open Normally Open O 6, 5 64 Connector 1 BR + 64 Connector 1 BR BK BL 3 - 5 LED LED *+ LOAD BK 2/4 BL * - LOAD 2/4 49 35 3 49 40 Normally Open Normally Open (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 35 PREVIOUS DC - 4 WIRE - COMPLEMENTARY OUTPUTS (N.O. & N.C.) Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V DC, 200mA 1 LED for Output Energized HOME mark NEXT FIND IT * Carries * IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection * Short Circuit Protection * Overload Protection * Reverse Polarity Protection * Wire Break Resistance * Temperature Range: -25 to 70C (-13 to 158F) M12 Flush Mount Sensing Distance Cable or Connector Style Cat. No. Cable 9962-6200 M12 Non-Flush Mount 4mm (.16 in.) Cable 9962-6300 2mm (.08 in.) 65 9962-6265 65 9962-6365 PNP NPN (Complementary NO/NC) (Complementary NO/NC) Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Cap Material 10% 10V-30V 15 mA 200 mA 2.4V 10 A 2000 Hz 15% 10% 10% 10V - 30V 15 mA 200 mA 2.4V 10 A 2000 Hz 15% 10% .20mm (.008 in.) PBTP 10% 10V - 30V 15 mA 200 mA 2.4V 10 A 1000 Hz 15% 10% .40mm (.016 in.) PBTB 10% 10V - 30V 15 mA 200 mA 2.4V 10 A 1000 Hz 15% 10% .40mm (.016 in.) PBTB .20mm (.008 in.) PBTP M 12 M 12 x 1 Fixed Cable PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.) cable length, change the last two digits of the part number to 02. For other cable lengths and/or PUR cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. 5 60 0 4 60 4 M LED 6 M 12 7 80 0 54 6 x 1 LED 12 36 (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 6 70 80 0 65 Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. LED LED PREVIOUS HOME NEXT FIND IT Accessories 2 meter (6 ft. 6 in.) DC Cable Assemblies for Quick Disconnect Sensors Metric/in. Conversion Table 1.0 mm = .04 in. 6.0 mm = .23 in. 8.0 mm = .31 in. 10.0 mm = .39 in. 12.0 mm = .47 in. 18.0 mm = .70 in. 32.0 mm = 1.26 in. 42.0 mm= 1.65 in. 44.0 mm 50.0 mm 51.0 mm 54.0 mm 60.0 mm 70.0 mm 80.0 mm = = = = = = = 1.73 in. 1.96 in. 2.0 in. 2.12 in. 2.36 in. 2.75 in. 3.12 in. This table converts millimeters to inches in reference to the illustrations included on these pages 65 Connectors, 4PIN - 4 Wire cable (PIN 1, 2, 3, 4) : 65 Connectors 8000-5280 PVC, Right Angle Change last digit of connector number for 5 meter cable Refer to pages 116-121 for more cable information M18 Flush Mount 5mm (.2 in.) Cable 9964-6200 M18 Non-Flush Mount 8mm (.31 in.) Cable 9964-6300 Mounting Brackets - see Pages 114-115 65 9964-6265 65 9964-6365 10% 10V - 30V 15 mA 200 mA 2.4V 10 A 1000 Hz 15% 10% .5mm (.02 in.) PBTB 10% 10V - 30V 15 mA 200 mA 2.4V 10 A 1000 Hz 15% 10% .5mm (.02 in.) PBTB 10% 10V - 30V 15 mA 200 mA 2.4V 10A 500 Hz 15% 10% .8mm (.031 in.) PBTB 10% 10V - 30V 15 mA 200 mA 2.4 V 10A 500 Hz 15% 10% .8mm (.031 in.) PBTB Note: Sensor dimensions in mm. Wiring Diagrams Note: Wire colors are applicable to cable purchased from Altech M 18 x 1 M 18 x 1 PNP LED LED 8 Cable Connector BR + BK (N.O.) WH (N.C.) LOAD BL 50 60 60 42 * - * PNP x 1 1 65 Connector M 18 x 1 M M 18 18 LED LED 1 BR + 4 BK(N.O.) LOAD 8 80 80 (N.C.) WHT 2 3 * BL LOAD - 10 (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 10 37 PREVIOUS DC - 3 WIRE - EXTENDED TEMPERATURE RANGE Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V DC, 200mA 1 LED for Output Energized HOME NEXT FIND IT * Temperature Range: -40 to 100C (104 to 212F) * Carries mark * IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection * Short Circuit Protection * Overload Protection * Reverse Polarity Protection * Wire Break Resistance M12 Flush Mount Sensing Distance Cable or Connector Style Cat. No. Cable 9962-6010 M12 Non-Flush Mount 4mm (.16 in.) Cable 9962-6110 2mm (.08 in.) 65 9962-6065 65 9962-6165 PNP NPN Normally Open Normally Closed Normally Open Normally Closed Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Cap Material 10% 10V-30V 10 mA 200 mA 2.4V 10 A 2000 Hz 15% 10% 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 2000 Hz 15% 10% .20mm (.008 in.) PBTP 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 1000 Hz 15% 10% .40mm (.016 in.) PBTB 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 1000 Hz 15% 10% .40mm (.016 in.) PBTB .20mm (.008 in.) PBTP Fixed Cable PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.) cable length, change the last two digits of the part number to 02. For other cable lengths and/or PUR cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. M 12 x 1 M 12 x 1 LED LED 40 34 M 12 12 x 1 x 6 M 1 LED LED 65 Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. 4 50 0 38 (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 60 60 50 34 6 PREVIOUS HOME NEXT FIND IT Accessories Metric/in. Conversion Table 1.0 mm 6.0 mm 8.0 mm 12.0 mm 18.0 mm = = = = = .04 in. .23 in. .31 in. .47 in. .70 in. 32.0 mm 34.0 mm 40.0 mm 50.0 mm 51.0 mm 60.0 mm = = = = = = 1.23 in. 1.31 in. 1.39 in. 1.47 in. 1.59 in. 2.36 in. 2 meter (6 ft. 6 in.) DC Cable Assemblies for Quick Disconnect Sensors This table converts millimeters to inches in reference to the illustrations included on these pages 65 Connector 65 Connector 65 Connector 65 Connector 8000-5110 8000-5120 8000-5150 8000-5160 PVC, Straight PVC, Right Angle PVC, Right Angle, 2LED, NPN PVC, Right Angle, 2LED, PNP Change last digit of connector number to 5 for 5 meter cable Refer to pages 116-121 for more cable information M18 Flush Mount 5mm (.20 in.) Cable 9964-6010 M18 Non-Flush Mount 8mm (.31 in.) Cable 9964-6110 65 9964-6065 65 9964-6165 Mounting Brackets - see Pages 114-115 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 1000 Hz 15% 10% .50mm (.02 in.) PBTB 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 1000 Hz 15% 10% .50mm (.02 in.) PBTB 10% 10V - 30V 25 mA 200 mA 2.4V 10A 500 Hz 15% 10% .80mm (.03 in.) PBTB 10% 10V - 30V 25 mA 200 mA 2.4V 10A 500 Hz 15% 10% .80mm (.03 in.) PBTB Note: Sensor dimensions in mm. Wiring Diagrams Note: Wire colors are applicable to cable purchased from Altech PNP 1 Fixed Cable BR M M 18 x 1 LED 18 x LED + 8 BK 40 32 40 LOAD BL *- Normally Open M M 18 x 1 18 x 1 65 Connector BR + 1 LED LED 4 BK LOAD 8 4 50 60 1 5 60 1 32 2 3 * BL - M (c)Altech 12 x 1 Normally Open Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 M 12 x 1 39 PREVIOUS DC - 3 WIRE - WELD IMMUNE Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V DC, 200mA 1 LED for Output Energized HOME NEXT FIND IT * IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection * Short Circuit Protection * Overload Protection * Reverse Polarity Protection * Wire Break Resistance * Temperature Range: -25 to 70C (-13 to 158F) * Circuitry that protects for electro-magnetic interference * Flush models have teflon ceramic coatings to protect for weld slag * Carries mark M12 Flush Mount Sensing Distance Cable or Connector Style Cat. No. M12 Non-Flush Mount 4mm (.16 in.) 45 Cable 9962-5900 2mm (.08 in.) Cable 9962-5840 9962-5845 65 9962-5965 PNP NPN Normally Open Normally Closed Normally Open Normally Closed Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Cap Material Housing Material 10% 10V-30V 10 mA 200 mA 2.4V 10 A 15 Hz 15% 10% 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 15 Hz 15% 10% .20mm (.008 in.) Teflon Teflon Plated Brass 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 15Hz 15% 10% .40mm (.016 in.) PBTB Nickel Plated Brass 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 15 Hz 15% 10% .40mm (.016 in.) PBTB Nickel Plated Brass .20mm (.008 in.) Teflon Teflon Plated Brass M M 12 12 10 10 Fixed Cable PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.) cable length, change the last two digits of the part number to 02. For other cable lengths and/or PUR cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. x x 1 1 50 50 M 12 6 x 1 10 70 6 LED LED M 12 x 1 45/65 Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. LED LED 40 (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 10 70 PREVIOUS HOME NEXT FIND IT Accessories Metric/in. Conversion Table 1.0 mm 6.0 mm 8.0 mm 10.0 mm 12.0 mm = = = = = .04 in. .23 in. .31 in. .39 in. .47 in. 50.0 mm 52.0 mm 60.0 mm 70.0 mm 80.0 mm = = = = = 1.47 in. 2.04 in. 2.36 in. 2.75 in. 3.12 in. 2 meter (6 ft. 6 in.) DC Cable Assemblies for Quick Disconnect Sensors This table converts millimeters to inches in reference to the illustrations included on these pages 45/65 Connector 8000-5110 45/65 Connector 8000-5120 45/65 Connector 8000-5150 45/65 Connector 8000-5160 PVC, Straight PVC, Right Angle PVC, Right Angle, 2LED, NPN PVC, Right Angle, 2LED, PNP Change last digit of connector number to 5 for 5 meter cable Refer to pages 116-121 for more cable information M18 Flush Mount 5mm (.20 in.) Cable 9964-5840 M18 Non-Flush Mount 8mm (.31 in.) Cable 9964-5900 Mounting Brackets - see Pages 114-115 45 9964-5845 65 9964-5965 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 15 Hz 15% 10% .50mm (.02 in.) Teflon Teflon Plated Brass 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 15 Hz 15% 10% .50mm (.02 in.) Teflon Teflon Plated Brass 10% 10V - 30V 10 mA 200 mA 2.4V 10A 15 Hz 15% 10% .80mm (.03 in.) PBTB Nickel Plated Brass 10% 10V - 30V 10 mA 200 mA 2.4V 10A 15 Hz 15% 10% .80mm (.03 in.) PBTB Nickel Plated Brass Note: Sensor dimensions in mm. Wiring Diagrams Note: Wire colors are applicable to cable purchased from Altech M PNP Fixed Cable BR 18 x M 18 x 1 1 LED LED + 8 BK LOAD BL *- 60 10 60 Normally Open 10 M M M 18 x x 1 LED 18 18 x 1 1 65 Connector BR + 1 8 LED 4 BK LOAD 2 3 * BL - 80 Normally Open (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 10 10 80 41 PREVIOUS DC - 3 WIRE - WELD IMMUNE Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V DC, 200mA 1 LED for Output Energized HOME NEXT FIND IT * Circuitry that protects for electro-magnetic interference * Flush models have teflon ceramic coatings to protect for weld slag * Carries mark * IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection * Short Circuit Protection * Overload Protection * Reverse Polarity Protection * Wire Break Resistance * Temperature Range: -25 to 70C (-13 to 158F) M30 Flush Mount Sensing Distance Cable or Connector Style Cat. No. M30 Non-Flush Mount 15mm (.59 in.) Cable 9966-5900 10mm (.39 in.) Cable 9966-5840 45/65 9966-5845 65 9966-5965 PNP NPN Normally Open Normally Closed Normally Open Normally Closed Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Cap Material Housing Material 10% 10V-30V 10 mA 200 mA 2.4V 10 A 15 Hz 15% 10% 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 15 Hz 15% 10% 1.0mm (.039 in.) Teflon Teflon Plated Brass 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 15 Hz 15% 10% 1.5mm (.059 in.) PBTB Nickel Plated Brass 10% 10V - 30V 10 mA 200 mA 2.4V 10 A 15Hz 15% 10% 1.5mm (.059 in.) PBTB Nickel Plated Brass 1.0mm (.039 in.) Teflon Teflon Plated Brass Note: Sensor dimensions in mm. M M 30 30 Fixed Cable PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.) cable length, change the last two digits of the part number to 02. For other cable lengths and/or PUR cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. x x 1, 5 LED 1, 5 LED 60 10 10 60 12 M 30 M 30 x 1, 5 LED x 1, 5 45/65 Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. LED 80 10 42 (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 10 80 12 PREVIOUS Metric/in. Conversion Table 1.5 mm = .06 in. 10.0 mm = .39 in. 12.0 mm = .47 in. 30.0 mm =1.20 in. 60.0 mm = 2.36 in. 80.0 mm= 3.15 in. HOME NEXT FIND IT This table converts millimeters to inches in reference to the illustrations included on these pages Accessories 2 meter (6 ft. 6 in.) DC Cable Assemblies for Quick Disconnect Sensors 45/65 Connector 8000-5110 45/65 Connector 8000-5120 45/65 Connector 8000-5150 45/65 Connector 8000-5160 PVC, Straight PVC, Right Angle PVC, Right Angle, 2LED, NPN PVC, Right Angle, 2LED, PNP Change last digit of connector number to 5 for 5 meter cable Refer to pages 116-121 for more cable information Mounting Brackets - see Pages 114-115 Wiring Diagrams Note: Wire colors are applicable to cable purchased from Altech PNP Fixed Cable BR BK LOAD BL + *- Normally Open 65 Connector BR + 1 4 BK LOAD 2 3 * BL - Normally Open (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 43 PREVIOUS DC ANALOG SENSORS Cylindrical,Threaded Brass, Nickel Plated (BN), 18-30V DC Analog Output 1V - 9V M12, M18, M30 M30 4 Bit Digital & Analog Output HOME NEXT FIND IT * IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection * Short Circuit Protection * Overload Protection * Temperature Range: -25 to 70C (-13 to 158F) * Output voltage proportional to target distance * Ideal for determining position information * Excellent linearity 3% * Shielded cable ouputs on cable models * Carries mark M12 Flush Mount Sensing Distance Cable or Connector Style Cat. No. Voltage Range Supply Current Max. Load Current Max. Switching Frequency Temperature Drift Repeatability Front Cap Material Output Voltage Range M18 Flush Mount 1mm (.04 in.) to 4mm (.16 in.) Cable 9914-0900 18V - 30V 10 mA 5 mA 100 Hz 0.3V 1% PBTB 1-9V DC 0.5mm (.02 in.) to 2.5mm (0.1 in.) Cable 9914-0800 18V-30V 10 mA 5 mA 100 Hz 0.3V 65 9914-0865 18V - 30V 10 mA 5 mA 100 Hz 0.3V 1% PBTP 1-9V DC 65 9914-0965 18V - 30V 10 mA 5 mA 100 Hz 0.3V 1% PBTB 1-9V DC 1% PBTP 1-9V DC M 12 x 1 M 18 x 1 Fixed Cable PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.) cable length, change the last two digits of the part number to 02. For other cable lengths and/or PUR cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. 7 80 0 7 80 0 M 12 x 1 M 18 x 1 65 Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. 80 44 (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 10 80 0 10 0 PREVIOUS 1.0 mm 1.5 mm 10.0 mm 12.0 mm 18.0 mm 30.0 mm HOME NEXT FIND IT Accessories Metric/in. Conversion Table = .04 in. = .06 in. = .40 in. = .47 in. = .70 in. =1.20 in. 58.0 mm = 2.28 In. 70.0 mm = 2.75 in. 80.0 mm = 3.12 in. 100.0mm = 3.94 in. This table converts millimeters to inches in reference to the illustrations included on these pages 2 meter (6 ft. 6 in.) DC Cable Assemblies for Quick Disconnect Sensors 65 Connectors, 4PIN - 4 Wire cable (PIN 1, 2, 3, 4) : 65 Connectors 8000-5280 PVC, Right Angle Change last digit of connector number to 5 for 5 meter cable Refer to pages 116-121 for more cable information M30 Non-Flush Mount 7mm (.28 in.) to 14mm (.55 in.) Cable 9914-1000 18V - 30V 10 mA 5 mA 30 Hz 0.3V 1% PBTB 1-9V DC & 4 Bit Digital Cable 9914-0500 18V - 30V 10 mA 5 mA 30 Hz 0.3V 1% PBTB 1-9V DC 65 9914-0565 18V - 30V 10 mA 5 mA 30 Hz 0.3V 1% PBTB 1-9V DC The analog output voltage can be digitized by the 8100-2100 switching unit and 8100-2400/2500 modules. (Separate Accessory items - refer to pages 125 & 126 for more information.) Mounting Brackets - see Pages 114-115 Wiring Diagrams Note: Wire colors are applicable to cable purchased from Altech Note: Sensor dimensions in mm. Fixed Cable M12, M18, M30 BR + 12 M 30 WHT x 1, 5 * * SHIELD WIRE LOAD BL - Fixed Cable M30 80 58 7 CONDUCTOR CABLE BR + GREY YEL PNK GR 4 BIT DIG. OUTPUT WHT * * BL SHIELD WIRE LOAD - 65CN M12, M18, M30 BR + 1 4 BK LOAD * 2 3 BL - WHT * Pin 2 connected internally to Pin 3. (Can be used as shield with shielded cable) (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 45 PREVIOUS DC - 3WIRE EXTENDED RANGE PLUS Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V DC, 200mA 1 LED for Output Energized HOME NEXT FIND IT * Up to 3 times the sensing distance * IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection * Sensing ranges from 3mm (.12 in.) to * Ideal for applications where large 40mm (1.57 in.) sensors will not fit * Short Circuit Protection * Carries mark * Overload Protection * Reverse Polarity Protection * Wire Break Resistance * Temperature Range: -25 to 70C (-13 to 158F) M8 Flush Mount Sensing distance Cable or Connector Style Cat. No. Cable 9981-5000 M8 Non-Flush Mount 6mm (0.2 in.) 65 9981-5065 3mm (0.1 in.) 64 9981-5064 Cable 9981-5200 64 9981-5264 65 9981-5265 PNP NPN Normally Open Normally Closed Normally Open Normally Closed Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Housing Material Repeatability 20% 10-30V 20mA 200mA 2.4V 100A 1000Hz 10% 10% Nickel Plated Brass .15mm (.005 in.) 20% 10-30V 20mA 200mA 2.4V 100A 1000Hz 10% 10% Nickel Plated Brass .15mm (.005 in.) 20 10-30V 20mA 200mA 2.4V 100A 1000Hz 10% 10% Nickel Plated Brass .15mm (.005 in.) 20% 10-30V 20mA 200mA 2.4V 100A 500Hz 10% 10% Nickel Plated Brass .3mm (.01 in.) 20% 10-30V 20mA 200mA 2.4V 100A 500Hz 10% 10% Nickel Plated Brass .3mm (.01 in.) 20% 10-30V 20mA 200mA 2.4V 100A 500Hz 10% 10% Nickel Plated Brass .3mm (.01 in.) M 8 LED LED M 8 Fixed Cable PVC 2m (6 ft. 6 in.). Supplied with Brass, Nickel Plated (BN) locknuts. 45 64 Connector 3-pin, Pico style, 8mm (.31 in.) supplied with Brass, Nickel Plated (BN) locknuts. LED 45 M 8 LED LED 4 46 5 60 4 LED x 1 M 8 x 1 65 Style Connectors 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. 4 66 58 4 46 (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 44 70 62 1 4 M 12 x 1 M 12 x 5 64 8 M 8 x 1 46 M 8 x 1 x 1 4 M 8 x 1 M 8 x 1 x 1 PREVIOUS 1.0 mm 4.0 mm 6.0 mm 8.0 mm 12.0 mm 40.0 mm 44.0 mm 45.0 mm 50.0 mm = = = = = = = = = .04 in. .16 in .23 in. .31 in. .47 in. 1.39 in. 1.73 in. 1.77 in. 1.97 in. HOME 52.0 mm 54.0 mm 56.0 mm 58.0 mm 60.0 mm 62.0mm 66.0 mm 70.0 mm = = = = = = = = 2.04 in. 2.12 in. 2.20 in. 2.28 in. 2.36 in. 2.44 in. 2.60 in. 2.75 in. NEXT FIND IT Accessories 2 meter (6 ft. 6 in.) DC Cable Assemblies for Quick Disconnect Sensors 64 Connector 8000-5220 PVC, Straight 64 Connector 8000-5230 PVC, Right Angle, 2LED,PNP 64 Connector 8000-5240 PVC, Right Anglr, 2 LED, NPN 65 Connector 8000-5110 PVC, Straight 65 Connector 8000-5120 PVC, Right Angle 65 Connector 8000-5150 PVC, Right Angle, 2LED NPN 65 Connector 8000-5160 PVC, Right Angle, 2LED PNP Metric/in. Conversion Table This table converts millimeters to inches in reference to the illustrations included on these pages M12 Flush Mount 6mm (0.2 in.) Cable 9982-5000 M12 Non-Flush Mount 10mm (0.4 in.) Cable 9982-5200 Change last digit of connector number to 5 for 5 meter cable Refer to pages 116-121 for more cable information Mounting Brackets - see Pages 114-115 65 65 9982-5065 9982-5265 Flush Installation Non-Flush Installation 2d Sn d 2d 20% 10-30V 20mA 200mA 2.4V 100A 800Hz 10% 10% Nickel Plated Brass .3mm (.01 in.) 20% 10-30V 20mA 200mA 2.4V 100A 800Hz 10% 10% Nickel Plated Brass .3mm (.01 in.) 20% 10-30V 20mA 200mA 2.4V 100A 400Hz 10% 10% Nickel Plated Brass .5mm (.02 in.) 20% 10-30V 20mA 200mA 2.4V 100A 400Hz 10% 10% Nickel Plated Brass .5mm (.02 in.) 0.2d d d d General Mounting - You must maintain minimum distance between adjacent and opposite sensors in addition to non-target metals as specified in the drawings above. Flush mount sensors must extend at least 0.2 times the sensor diameter above the adjacent metal housing. Non-flush mount sensors must extend a distance greater than the sensing distance (Sn). Please contact Altech for any installation assistance Wiring Diagrams Note: Wire colors are applicable to cable purchased from Altech Note: Sensor dimensions in mm. PNP Fixed Cable BR LED LED + 6 BK LOAD BL 4 56 0 4 50 0 *- Normally Open 64 Connector 1 BR BK 2/4 3 LOAD BL * - + Normally Open LED LED 65 Connector BR + 1 6 4 BK LOAD 4 58 0 40 5 60 2 2 3 * BL - 66 Normally Open (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 3 x Sn Metal Material M 12 x 1 M 12 x 1 M M 12 x 1 M 12 x 1 M 12 x 1 12 x 1 47 PREVIOUS DC - 3WIRE EXTENDED RANGE PLUS Brass, Nickel Plated (BN), Cylindrical,Threaded, 10-30V DC, 200mA 1 LED for Output Energized HOME NEXT FIND IT * Up to 3 times the sensing distance * Ideal for applications where large sensors will not fit * Carries mark * IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection * Sensing ranges from 3mm (.12 in.) to 40mm (1.57 in.) * Short Circuit Protection * Overload Protection * Reverse Polarity Protection * Wire Break Resistance * Temperature Range: -25 to 70C (-13 to 158F) M18 Flush Mount Sensing Distance Cable or Connector Style Cat. No. Cable 9984-5000 M18 Non-Flush Mount 20mm (0.8 in.) Cable 9984-5200 12mm (0.4 in.) 65 9984-5065 65 9984-5265 PNP NPN Normally Open Normally Closed Normally Open Normally Closed Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Housing Material Repeatability 20% 10V-30V 20 mA 200 mA 2.4V 100 A 500 Hz 10% 10% Nickel Plated Brass 0.6mm (.02 in.) 20% 10V - 30V 20 mA 200 mA 2.4V 100 A 500 Hz 10% 10% Nickel Plated Brass 0.6mm (.02 in.) 20% 10V - 30V 20 mA 200 mA 2.4V 100 A 200 Hz 10% 10% Nickel Plated Brass 1mm (.04 in.) 20% 10V - 30V 20 mA 200 mA 2.4V 100 A 200 Hz 10% 10% Nickel Plated Brass 1mm (.04 in.) M M 18 LED 18 x 4 50 0 40 LED LED 65 Style Connectors 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. 4 50 0 40 48 (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 6 74 0 64 10 M M 12 12 x x 1 1 60 M 18 x 1 10 M 18 x 1 Fixed Cable PVC 2m (6 ft. 6 in.). Supplied with Brass, Nickel Plated (BN) locknuts. LED x 1 1 PREVIOUS HOME NEXT FIND IT Accessories 2 meter (6 ft. 6 in.) DC Cable Assemblies for Quick Disconnect Sensors Metric/in. Conversion Table 1.0 mm 4.0 mm 6.0 mm 8.0 mm 12.0 mm 40.0 mm 44.0 mm 45.0 mm 50.0 mm = = = = = = = = = .04 in. .16 in .23 in. .31 in. .47 in. 1.57 in. 1.73 in. 1.77 in. 1.97 in. 52.0 mm 54.0 mm 56.0 mm 58.0 mm 60.0 mm 62.0mm 66.0 mm 70.0 mm = = = = = = = = 2.04 in. 2.12 in. 2.20 in. 2.28 in. 2.36 in. 2.44 in. 2.60 in. 2.75 in. This table converts millimeters to inches in reference to the illustrations included on these pages 65 Connector 65 Connector 65 Connector 65 Connector 8000-5110 8000-5120 8000-5150 8000-5160 PVC, Straight PVC, Right Angle PVC, Right Angle, 2LED NPN PVC, Right Angle, 2LED PNP Change last digit of connector number to 5 for 5 meter cable Refer to pages 116-121 for more cable information M30 Flush Mount 22mm (0.9 in.) Cable 9986-5000 M30 Non-Flush Mount 40mm (1.57 in.) Cable 9986-5200 Mounting Brackets - see Pages 114-115 65 9986-5065 65 9986-5265 Flush Installation Non-Flush Installation 2d 3 x Sn Sn d 2d 20% 10V - 30V 20 mA 200 mA 2.4V 100 A 300 Hz 10% 10% Nickel Plated Brass 1.1mm (.045 in.) 20% 10V - 30V 20 mA 200 mA 2.4V 100 A 300 Hz 10% 10% Nickel Plated Brass 1.1mm (.045 in.) 20% 10V - 30V 20 mA 200 mA 2.4V 100A 100 Hz 10% 10% Nickel Plated Brass 2mm (.078 in.) 20% 10V - 30V 20 mA 200 mA 2.04V 100A 100 Hz 15% 10% Nickel Plated Brass 2mm (.078 in.) 0.2d d d d Metal Material General Mounting - You must maintain minimum distance between adjacent and opposite sensors in addition to non-target metals as specified in the drawings above. Flush mount sensors must extend at least 0.2 times the sensor diameter above the adjacent metal housing. Non-flush mount sensors must extend a distance greater than the sensing distance (Sn). Please contact Altech for any installation assistance Note: Sensor dimensions in mm. Wiring Diagrams Note: Wire colors are applicable to cable purchased from Altech M PNP M 30 30 x LED 1. 10 5 60 0 50 LED 70 x 1. 5 M 30 x 1. 5 LED 5 M 30 x 5 1. Fixed Cable BR BK LOAD BL + *- Normally Open LED 65 Connector BR + 1 4 BK LOAD 10 5 60 0 70 50 74 (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 84 M 12 x 1 2 3 * BL - M 12 x 1 Normally Open 49 PREVIOUS DC - 2 WIRE NAMUR Brass, Nickel Plated (BN), and Plastic (TROGAMID-T) Cylindrical,Threaded HOME NEXT FIND IT * Low energy device * Operates in hazardous areas with external amplifier * Meets NAMUR regulations and DIN 19234 specifications * Carries mark * IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection * Reverse Polarity Protection * Plastic and Metal Housing according to NAMUR Regulations and DIN 19234 * Temperature Range: -25 to 70C (-13 to 158F) (For extended temperature models of -40C to +125C, consult Altech.) M8 Flush Mount Sensing Distance Cable or Connector Style Cat. No. Nickel Plated Brass (BN) Plastic (TROGAMID T) Ripple Voltage Voltage Range (supplied by Pulsotronic 8100-2200 Unit) Output Current ( with target detection) Output Current ( no target detection) Switching Frequency Hysterisis Temperature Drift Repeatability Front Cap Material 5% 8.2V DC at 1K 5% 8.2V DC at 1K 0.5 mA 3.5 mA 2000 Hz 15% 10% .1mm (.004 in.) PBTP (Metal Housing) M8 Non-Flush Mount 2mm (.08 in.) Cable 9932-0200 9932-1600 15% 8.2V DC at 1K 0.5 mA 3.5 mA 1000 Hz 15% 10% .2mm (.008 in.) PBTP (Metal Housing) 5% 8.2V DC at 1K 1mm (.04 in.) Cable 9932-0100 65 9932-0165 65 9932-0265 0.5 mA 3.5 mA 2000 0Hz 15% 10% 0.5 mA 3.5 mA 1000 Hz 15% 10% .2mm (.008 in.) PBTP (Metal Housing) .1mm (.004 in.) PBTP (Metal Housing) M M Fixed Cable PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.) cable length, change the last two digits of the part number to 02. For other cable lengths and/or PUR cable, please consult Altech. Non-metallic locknuts for M8 and Brass, Nickel Plated (BN) locknuts for M12 through M30. 30 25 30 M 8 x x 1 1 50 1 23 M 12 x 5 65 Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with non-metallic locknuts for M8 and Brass, Nickel Plated (BN) locknuts for M12 through M30. 50 (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 50 28 5 M 8 M 12 x 1 8 x 1 8 x 1 PREVIOUS 1.0 mm 5.0 mm 6.0 mm 8.0 mm 12.0 mm 23.0mm = = = = = = .04 in. .20 in. .23 in. .31 in. .47 in. .91 in. HOME 24.0 mm 25.0 mm 28.0 mm 30.0 mm 40.0 mm 50.0 mm = = = = = = .94 in. 1.0 in. 1.16 in 1.20 in. 1.57 in. 1.97 in. NEXT FIND IT Accessories 2 meter (6 ft. 6 in.) DC Cable Assemblies for Quick Disconnect Sensors Metric/in. Conversion Table This table converts millimeters to inches in reference to the illustrations included on these pages 65 Connectors, 4 PIN - 4 Wire cable (PIN 1, 2, 3, 4) : 65 Connector 8000-5280 PVC Right Angle Channge last digit of connector number to 5 for 5 meter cable Refer to pages 116-121 for more cable information M12 Flush Mount 2mm (.08 in.) Cable 9932-0300 9932-1100 15% 8.2V DC at 1K 5% 8.2V DC at 1K 0.5 mA 3.5 mA 2000 Hz 15% 10% .2mm (.008 in.) PBTP (Metal Housing) M12 Non-Flush Mount 4mm (.16 in.) Cable 9932-0400 9932-1000 5% 8.2V DC at 1K 0.5 mA 3.5 mA 1000 Hz 15% 10% .4mm (.016 in.) PBTP (Metal Housing) 5% 8.2V DC at 1K 0.5 mA 3.5 mA 1000 Hz 15% 10% .4mm (.016 in.) PBTP (Metal Housing) Remote Amplifier - Use 8100-2200, see page 123 65 9932-0365 65 9932-0465 Mounting Brackets - see Pages 114-115 0.5 mA 3.5 mA 2000 Hz 15% 10% .2mm (.008 in.) PBTP (Metal Housing) Note: Sensor dimensions in mm. Wiring Diagrams Note: Wire colors are applicable to cable purchased from Altech 30 24 6 6 3 40 50 0 24 40 M 12 x 1 M 12 x 1 M 12 x 1 Fixed Cable BR + Remote Amplifier BL - M 12 x 1 1 65 Connector BR + 4 Remote Amplifier 2 3 WHT - (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 50 M 12 x 1 51 PREVIOUS DC - 2 WIRE NAMUR Brass, Nickel Plated (BN), and Plastic (TROGAMID-T) Cylindrical,Threaded HOME NEXT FIND IT * Low energy device * Operates in hazardous areas with external amplifier * Meets NAMUR regulations and DIN 19234 specifications * Carries mark * IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection * Reverse Polarity Protection * Plastic and Metal Housing according to NAMUR Regulations and DIN 19234 * Temperature Range: -25 to 70C (-13 to 158F) M18 Flush Mount Sensing Distance Cable or Connector Style Cat. No. Nickel Plated Brass (BN) Plastic (TROGAMID T) Ripple Voltage Voltage Range (supplied by Pulsotronic 8100-2200 Unit) Output Current ( with target detection) Output Current ( no target detection) Switching Frequency Hysterisis Temperature Drift Repeatability Front Cap Material Cable 9932-0500 9932-1300 5% 8.2V DC at 1K 0.5 mA 3,5 mA 1000 0Hz 15% 10% 5% 8.2V DC at 1K 0.5 mA 3.5 mA 1000 Hz 15% 10% .5mm (.02 in.) PBTP (Metal Housing) M18 Non-Flush Mount 8mm (.31 in.) Cable 9932-0600 9932-1200 5% 8.2V DC at 1K 0.5 mA 3.5 mA 500 Hz 15% 10% .8mm (.03 in.) PBTP (Metal Housing) 5% 8.2V DC at 1K 0.5 mA 3.5 mA 500 Hz 15% 10% .8mm (.03 in.) PBTP (Metal Housing) 5mm (.20 in.) 65 9932-0565 65 9932-0665 .5mm (.02 in.) PBTP (Metal Housing) Fixed Cable PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.) cable length, change the last two digits of the part number to 02. For other cable lengths and/or PUR cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. M 30 22 M 1 40 22 M 12 x 1 30 18 x 1 8 3 40 50 0 65 Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. 52 (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 50 8 M 18 x M 12 x 1 M 18 x 1 18 x 1 PREVIOUS HOME NEXT FIND IT Accessories Metric/in. Conversion Table 1.0 mm 1.5 mm 8.0 mm 12.0 mm 18.0 mm 22.0 mm = = = = = = .04 in. .06 in. .31 in. .47 in. .70 in. .86 in. 28.0 mm 30.0 mm 40.0 mm 50.0 mm 51.0 mm 60.0 mm = = = = = = 1.16 in 1.20 in. 1.57 in. 1.96 in. 2.00 in. 2.36 in. 2 meter (6 ft. 6 in.) DC Cable Assemblies for Quick Disconnect Sensors This table converts millimeters to inches in reference to the illustrations included on these pages 65 Connectors, 4 PIN - 4 Wire cable (PIN 1, 2, 3, 4) : 65 Connector 8000-5280 PVC Right Angle Change last digit of connector number to 5 for 5 meter cable Refer to page s 116-121 for more cable information M30 Flush Mount 10mm (.39 in.) Cable 9932-0700 9932-1500 5% 8.2V DC at 1K 0.5 mA 3.5 mA 500 Hz 15% 10% .1mm (.039 in.) PBTP (Metal Housing) 5% 8.2V DC at 1K 0.5 mA 3.5 mA 500 Hz 15% 10% .1mm (.039 in.) PBTP (Metal Housing) M30 Non-Flush Mount 15mm (.59 in.) Cable 9932-0800 9932-1400 5% 8.2V DC at 1K 0.5 mA 3.5 mA 300 Hz 15% 10% 1.5mm (.059 in.) PBTP (Metal Housing) 5% 8.2V DC at 1K 0.5 mA 3.5 mA 300 Hz 15% 10% 1.5mm (.059 in.) PBTP (Metal Housing) 65 9932-0765 65 9932-0865 Remote Amplifier - Use 8100-2200, see page 123 Mounting Brackets - see Pages 114-115 Note: Sensor dimensions in mm. Wiring Diagrams Note: Wire colors are applicable to cable purchased from Altech M 12 40 28 40 12 M 30 x 1, 5 M 30 x 1, 5 M 30 x 1, 5 Fixed Cable BR + Remote Amplifier BL - M 30 x 1, 5 65 Connector BR 1 + 4 Remote Amplifier 2 3 WHT - 4 50 60 1 (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 4 50 60 1 M 12 x 1 12 x 1 53 PREVIOUS DC - 2 WIRE SENSORS Brass, Nickel Plated (BN), Cylindrical,Threaded, M12 - 5-30V DC, 100mA M18, M30 - 10-55V DC, 200 mA 1 LED for Output Energized HOME NEXT FIND IT * 2 Wire devices reduce wiring requirements * Economically Priced * Carries mark * IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection * Reverse Polarity Protection * Temperature Range: -25 to 70C (-13 to 158F) M12 Flush Mount Sensing distance Cable or Connector Style Cat. No. Normally Open Normally Closed M12 Non-Flush Mount 4mm (.16 in.) Cable 9962-5700 M18 Flush Mount 5mm (0.2 in.) Cable 9964-5400 2mm (.08 in.) Cable 9962-5600 65 9962-5665 65 9962-5765 Ripple Voltage Voltage Range Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Switching Frequency Hysterisis Temperature Drift Repeatability Front Cap Material 10% 5V-30V 3mA 100mA 5V 0.5mA 500Hz 15% 10% .20mm (.008 in.) PBTP 10% 5V-30V 3mA 100mA 5V 0.5mA 500Hz 15% 10% .20mm (.008 in.) PBTP 10% 5V-30V 3mA 100mA 5V 0.5mA 500Hz 15% 10% .40mm (.016 in.) PBTP 10% 5V-30V 3mA 100mA 5V 0.5mA 500Hz 15% 10% .40mm (.016 in.) PBTP 10% 10V-55V 5mA 200mA 6.5V 1.5mA 1000Hz 15% 10% .40mm (.016 in.) PBTP Fixed Cable PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.) cable length, change the last two digits of the part number to 02. For other cable lengths and/or PUR cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. M M 12 x 18 M 12 x 1 LED LED x 1 LED 1 6 45 35 4 50 60 0 65 Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. 45 LED LED 54 (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 60 50 34 6 5 60 0 29 M 12 x 1 M 12 x 1 PREVIOUS 1.5 mm 2.0 mm 4.0 mm 5.0 mm 6.0 mm 8.0 mm 10.0 mm 12.0 mm 15.0 mm 18.0 mm = = = = = = = = = = .06 in. .08 in. .16 in .20 in. .23 in. .31 in. .39 in. .47 in. .59 in. .70 in. HOME 23.0 mm 28.0 mm 30.0 mm 32.0 mm 34.0 mm 40.0 mm 50.0 mm 51.0 mm 60.0 mm 80.0 mm = = = = = = = = = = .08 in. 1.10 in 1.18 in. 1.26 in. 1.34 in. 1.57 in. 1.97 in. 2.01 in. 2.36 in. 3.12 in. NEXT FIND IT Accessories 2 meter (6 ft. 6 in.) DC Cable Assemblies for Quick Disconnect Sensors Metric/in. Conversion Table This table converts millimeters to inches in reference to the illustrations included on these pages 65 Connector 65 Connector 8000-5110 PVC, Straight 8000-5120 PVC, Right Angle Change last digit of connector number to 5 for 5 meter cable Refer to pages 116-121 for more cable information M18 Non-Flush Mount M30 Flush Mount M30 Non-Flush Mount 8mm (.31 in.) Cable 9964-5500 Mounting Brackets - see Pages 114-115 10mm (.39 in.) Cable 9966-5400 15mm (.59 in.) Cable 9966-5500 10% 10V-55V 5mA 200mA 6.5V 1.5mA 500Hz 15% 10% .80mm (.03 in.) PBTP 10% 10V-55V 5mA 200mA 6.5V 1.5mA 500Hz 15% 10% 1mm (.039 in.) PBTP 10% 10V-55V 5mA 200mA 6.5V 1.5mA 300Hz 15% 10% 1.5mm (.059 in.) PBTP Note: Sensor dimensions in mm. Wiring Diagrams Note: Wire colors are applicable to cable purchased from Altech M M M 18 x 1 Fixed Cable BR 30 30 x 1, 5 x 1, 5 LED LED LED + LOAD 42 8 60 12 5 60 0 38 BL - 60 65 Connector BR 1 + LOAD BLK - 4 2 3 (c)Altech Corp. * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 55 PREVIOUS AC - 2 WIRE STANDARD SERIES Brass, Nickel Plated (BN), Cylindrical,Threaded, 90-250V AC, 180 mA, 1 LED for Output Energized HOME NEXT FIND IT * IEC (529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection * Temperature Range: -25 to 70C (-13 to 158F) * Most complete range of Fixed Cable and Quick Disconnect Styles * Available in normally open (N.O.) and normally closed (N.C.) output configuration * This series features the 360 LED viewing connector type "67" * Carries mark M12 Flush Mount Sensing Distance Cable or Connector Style Cat. No. Normally Open Normally Closed Voltage Range Operating Frequency Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Short Term Current (20ms 1Hz) Switching Frequency Hysterisis Temperature Drift Repeatability Front Cap Material Cable 9952-0500 M12 Non-Flush Mount 4mm (.16 in.) 68 9952-0568 2mm (.08 in.) 62 9952-0562 66/67 9952-0566 9952-0567 Cable 9952-0400 62 9952-0462 66/67 9952-0466 9952-0467 68 9952-0468 9952-0900 9952-0966 9952-0967 9952-0968 9952-0800 9952-0866 9952-0867 9952-0868 90V-250V 50/60Hz 5 mA 180 mA 8V 3mA/220V 1.5mA/110V 1A 15Hz/220V 15% 10% .2mm (.008in.) PBTP 90V - 250V 50/60Hz 5 mA 100 mA 8V 3mA/220V 1.5mA/110V 1A 15Hz/220V 15% 10% .2mm (.008in.) PBTP 90V - 250V 50/60Hz 5 mA 180 mA 8V 3mA/220V 1.5mA/110V 1A 15Hz/220V 15% 10% .2mm (.008in.) PBTP 90V - 250V 50/60Hz 5 mA 180 mA 8V 3mA/220V 1.5mA/110V 1A 15Hz/220V 15% 10% .2mm (.008in.) PBTP 90V - 250V 50/60Hz 5 mA 180 mA 8V 3mA/220V 1.5mA/110V 1A 15Hz/220V 15% 10% 90V - 250V 50/60Hz 5 mA 180 mA 8V 3mA/220V 1.5mA/110V 1A 15Hz/220V 15% 10% 90V - 250V 50/60Hz 5 mA 180 mA 8V 3mA/220V 90V - 250V 50/60Hz 5 mA 180 mA 8V 3mA/220V 1.5mA/110V 1.5mA/110V 1A 15Hz/220V 15% 10% 1A 15Hz/220V 15% 10% .4mm (.016in.) .4mm (.0016in.) .4mm (.016in.) .4mm (.016in.) PBTB PBTB PBTB PBTB M M 12 12 Fixed Cable PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.) cable length, change the last two digits of the part number to 02. For other cable lengths and/or PUR cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. x LED 5 60 0 60 M 12 x 1 M 12 x 1 LED LED 91 27 10 10 27 91 62 Style Connector 3-pin, Mini style, 25mm (1.0 in.) supplied with Brass, Nickel Plated (BN) locknuts. 26 44 54 54 66/67/68 Style Connectors The 66/67 connectors are 4-pin, (68 connector, 3-pin), Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. The 67 Connector is clear, offering 360 LED viewing. LED (66/68 CN) LED (67 CN) LED (66/68 CN) LED (67 CN) 6 26 6 M 12 x 1 60 34 6 x 1 LED 1 56 Altech Corp.(R) * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 60 40 M 12 x 1 PREVIOUS 1.0 mm 5.0 mm 6.0 mm 8.0 mm 12.0 mm 23.0 mm 28.0 mm = .04 in. = .20 in. = .23 in. = .31 in. = .47 in. = .90 in. =1.10 in. HOME 29.0 mm 34.0 mm 35.0 mm 40.0 mm 43.0 mm 50.0 mm 60.0 mm = = = = = = = 1.14 in. 1.34 in. 1.37 in. 1.57 in. 1.69 in. 1.47 in. 2.36 in. NEXT FIND IT Accessories 2 meter (6 ft. 6 in.) AC Cable Assemblies for Quick Disconnect Sensors 62 Connector 8000-5030 66/67 Connector 8000-5060 66/67 Connector 8000-5070 68 Connector 8000-5130 68 Connector 8000-5140 PVC, Straight PVC, Right Angle PVC, Straight PVC Straight Right Angle Metric/in. Conversion Table This table converts millimeters to inches in reference to the illustrations included on these pages Change last digit of connector number to 5 for 5 meter cable Refer to pages 116-121 for more cable information M18 Flush Mount 5mm (0.2 in.) Cable 9954-2200 M18 Non-Flush Mount 8mm (.31 in.) 68 9954-2268 Mounting Brackets - see Pages 114-115 68 9954-1968 62 9954-2262 66/67 9954-2266 9954-2267 Cable 9954-1900 62 9954-1962 66/67 9954-1966 9954-1967 9954-2600 9954-2666 9954-2667 9954-2668 9954-2500 9954-2568 90V - 250V 50/60Hz 5 mA 180 mA 8V 3mA/220V 1.5mA/110V 1A 15Hz/220V 15% 10% .5mm (.02in.) PBTB 90V - 250V 50/60Hz 5 mA 180 mA 8V 3mA/220V 1.5mA/110V 1A 15Hz/220V 15% 10% .5mm (.02in.) PBTB 90V - 250V 50/60Hz 5 mA 180 mA 8V 3mA/220V 1.5mA/110V 1A 15Hz/220V 15% 10% .5mm (.02in.) PBTB 90V - 250V 50/60Hz 5 mA 180 mA 8V 3mA/220V 1.5mA/110V 1A 15Hz/220V 15% 10% .5mm (.02in.) PBTB 90V - 250V 50/60Hz 5 mA 180 mA 8V 3mA/220V 1.5mA/110V 1A 15Hz/220V 15% 10% .8mm (.031in.) PBTB 90V - 250V 50/60Hz 5 mA 180 mA 8V 3mA/220V 1.5mA/110V 1A 15Hz/220V 15% 10% .8mm (.031in.) PBTB 90V - 250V 50/60Hz 5 mA 180 mA 8V 3mA/220V 1.5mA/110V 1A 15Hz/220V 15% 10% .8mm (.031in.) PBTB 90V - 250V 50/60Hz 5 mA 180 mA 8V 3mA/220V 1.5mA/110V 1A 15Hz/220V 15% 10% .8mm (.031in.) PBTB Wiring Diagrams Note: Wire colors are applicable to cable purchased from Altech Fixed Cable BR Note: Sensor dimensions in mm. M 18 x 1 M 18 x 1 Fixed Cable BR BL LOAD Yellow/GRN BL LOAD Yellow/GRN LED LED Normally Open Normally Closed 5 60 0 60 42 8 62 Connector 1 GRN WHT 2 3 BLK LOAD M M 1 18 x 1 LED 8 18 x x 1 1 LED Normally Open 54 8 66/67 Connector Yell/GRN 4 3 BL 1 54 66/67 Connector Yell/GRN 4 3 BL 1 91 27 10 10 27 26 91 LED (67 CN) 8 40 3 60 2 60 Altech Corp.(R) * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 26 2 LOAD BLK 2 BLK LOAD Normally Open Normally Closed LED (66/68 CN) LED (66/68 CN) M M 18 x 1 18 x 1 68 Connector Red/WHT 3 2 Red GRN 1 LOAD GRN 1 LED (67 CN) 68 Connector Red/WHT 3 2 Red LOAD Normally Open Normally Closed 57 PREVIOUS AC - 2 WIRE STANDARD SERIES Brass, Nickel Plated (BN), Cylindrical,Threaded, 90-250V AC, 180 mA, 1 LED for Output Energized HOME NEXT FIND IT * IEC (529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection * Temperature Range: -25 to 70C (-13 to 158F) * Most complete range of Fixed Cable and Quick Disconnect Styles * Available in normally open (N.O.) and normally closed (N.C.) output configuration * This series features the 360 LED viewing connector type "67" * Carries mark M30 Flush Mount Sensing Distance Cable or Connector Style Cat. No. Normally Open Normally Closed Voltage Range Operating Frequency Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Current Short Term Current (20ms 1Hz) Switching Frequency Hysterisis Temperature Drift Repeatability Front Cap Material Cable 9956-1500 10mm (.39 in.) 62 9956-1562 66 9956-1566 67 9956-1567 68 9956-1568 9956-1900 9956-1968 90V - 250V 50/60Hz 5 mA 180 mA 8V 3A/220V 1.5mA/110V 1A 15Hz/220V 15% 10% 1mm (.039 in.) PBTP 90V - 250V 50/60Hz 5 mA 100 mA 8V 3A/220V 1.5mA/110V 1A 15Hz/220V 15% 10% 1mm (.039 in.) PBTP 90V - 250V 50/60Hz 5 mA 180 mA 8V 3A/220V 1.5mA/110V 1A 15Hz/220V 15% 10% 1mm (.039 in.) PBTP 90V - 250V 50/60Hz 5 mA 180 mA 8V 3A/220V 1.5mA/110V 1A 15Hz/220V 15% 10% 1mm (.039 in.) PBTP 90V - 250V 50/60Hz 5 mA 180 mA 8V 3A/220V 1.5mA/110V 1A 15Hz/220V 15% 10% 1mm (.039 in.) PBTB M 30 Fixed Cable PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.) cable length, change the last two digits of the part number to 02. For other cable lengths and/or PUR cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. x 1, 5 LED 5 60 0 M 30 x 1, 5 LED 62 Style Connector 3-pin, Mini style, 25mm (1.0 in.) supplied with Brass, Nickel Plated (BN) locknuts. 26 LED (66/68 CN) 10 25 91 56 M 30 x 1 66/67/68 Style Connectors The 66/67 connectors are 4-pin, (68 connector, 3-pin), Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts . The 67 Connector is clear, offering 360 LED viewing. LED (67 CN) 58 Altech Corp.(R) * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 70 50 PREVIOUS 1.0 mm 5.0 mm 6.0 mm 8.0 mm 12.0 mm 23.0 mm 28.0 mm = .04 in. = .20 in. = .23 in. = .31 in. = .47 in. = .90 in. =1.10 in. HOME 29.0 mm 34.0 mm 35.0 mm 40.0 mm 43.0 mm 50.0 mm 60.0 mm = = = = = = = 1.14 in. 1.34 in. 1.37 in. 1.57 in. 1.69 in. 1.97 in. 2.36 in. NEXT FIND IT Accessories 2 meter (6 ft. 6 in.) AC Cable Assemblies for Quick Disconnect Sensors 62 Connector 8000-5030 66/67 Connector 8000-5060 66/67 Connector 8000-5070 68 Connector 8000-5130 68 Connector 8000-5140 PVC, Straight PVC, Right Angle PVC, Straight PVC Straight Right Angle Metric/in. Conversion Table This table converts millimeters to inches in reference to the illustrations included on these pages Change last digit of connector number to 5 for 5 meter cable Refer to pages 116-121 for more cable information M30 Non-Flush Mount 15mm (0.59 in.) Cable 9956-1400 Mounting Brackets - see Pages 114-115 67 9956-1467 62 9956-1462 66 9956-1466 68 9956-1468 9956-1800 9956-1868 90V - 250V 50/60Hz 5 mA 180 mA 8V 3A/220V 1.5mA/110V 1A 15Hz/220V 15% 10% 1.5mm (.0596in.) PBTB 90V - 250V 50/60Hz 5 mA 180 mA 8V 3A/220V 1.5mA/110V 1A 15Hz/220V 15% 10% 1.5mm (.059 in.) PBTB 90V - 250V 50/60Hz 5 mA 180 mA 8V 3A/220V 1.5mA/110V 1A 15Hz/220V 15% 10% .4mm (.016in.) PBTB 90V - 250 50/60Hz 5 mA 180 mA 8V 3A/220V 1.5mA/110V 1A 15Hz/220V 15% 10% .4mm (.016in.) PBTB 90V - 250V 50/60Hz 5 mA 180 mA 8V 3A/220V 1.5mA/110V 1A 15Hz/220V 15% 10% .5mm (.02in.) PBTB Wiring Diagrams Note: Wire colors are applicable to cable purchased from Altech Fixed Cable BR Note: Sensor dimensions in mm. M 30 x 1, 5 Fixed Cable BR BL LOAD Yellow/GRN BL LOAD Yellow/GRN LED Normally Open Normally Closed 60 38 12 62 Connector 1 GRN WHT 2 3 BLK LOAD M 30 x 1, 5 LED Normally Open 12 66/67 Connector 66/67 Connector Yell/GRN 4 3 BL 1 56 25 91 Yell/GRN 4 3 BL 10 LED (67 CN) 68 Connector Red/WHT 3 2 Red GRN LOAD GRN 1 12 3 70 8 (c)Altech Corp.(R) * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 26 1 2 LOAD BLK 2 BLK LOAD Normally Open LED (66/68 CN) Normally Closed M 30 x 1, 5 68 Connector Red/WHT 3 2 Red LOAD 1 Normally Open Normally Closed 59 PREVIOUS AC - 2 WIRE - EXTENDED VOLTAGE RANGE - Brass, Nickel Plated (BN), and TROGAMID T Cylindrical,Threaded, 20-250V AC, 500 mA, 1 LED for Output Energized HOME NEXT FIND IT * IEC (529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection * Temperature Range: -25 to 70C (-13 to 158F) * Higher Current Rating * Wider Voltage Range * Carries mark M12 Flush Mount Sensing Distance Cable or Connector Style Cat. No. Normally Open Normally Closed Voltage Range Operating Frequency Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Short Term Current (20 ms, 1Hz) Switching Frequency Hysterisis Temperature Drift Repeatability Front Cap Material Housing Material Cable 9924-0500 M12 Non-Flush Mount 4mm (.16 in.) 68 Cable 9924-0700 2mm (.08 in.) Cable 9924-1100 9924-0568 Cable 9924-1000 68 9924-0768 9924-0400 9924-1300 9924-0468 9924-0900 9924-1200 9924-0968 20V-250V 50/60Hz 2 mA 300 mA 5V 2mA 2A 15Hz 15% 10% .20mm (.008 in.) PBTP Nickel Plated Brass 20V - 250V 50/60Hz 2 mA 300 mA 5V 2mA 2A 15Hz 15% 10% .20mm (.008 in.) PBTP Trogamid T 20V - 250V 50/60Hz 2 mA 300 mA 5V 2mA 2A 15Hz 15% 10% .20mm (.008 in.) PBTP Nickel Plated Brass 20V - 250V 50/60Hz 2 mA 300 mA 5V 2mA 2A 15Hz 15% 10% .40mm (.016 in.) PBTB Nickel Plated Brass 20V - 250V 50/60Hz 2 mA 300 mA 5V 2mA 2A 15Hz 15% 10% .40mm (.016 in.) PBTB Trogamid T 20V - 250V 50/60Hz 2 mA 300 mA 5V 2mA 2A 15Hz 15% 10% .40mm (.016 in.) PBTB Nickel Plated Brass M 12 x 1 M 12 x 1 Nickel Plated Brass Housings Fixed Cable PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.) cable length, change the last two digits of the part number to 02. For other cable lengths and/or PUR cable, please consult Altech. Supplied with non-metallic locknuts for Trogamid T housings and Nickel Plated (BN) locknuts for Nickel Plated Brass housings. Trogamid T Housings LED LED 6 70 0 70 M 12 x 1 6 M 12 54 6 x 1 70 LED LED 80 80 64 M M 12 x 1 12 x 1 60 Altech Corp.(R) * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 80 80 54 68 Style Connectors 3-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. LED LED 60 6 PREVIOUS HOME NEXT FIND IT Accessories 2 meter (6 ft. 6 in.) AC Cable Assemblies for Quick Disconnect Sensors Metric/in. Conversion Table 1.0 mm 6.0 mm 8.0 mm 12.0 mm 54.0 mm = .04 in. = .23 in. = .31 in. = .47 in. =2.12 in. 60.0 mm 64.0 mm 70.0 mm 80.0 mm = = = = 2.36 in. 2.52 in. 2.75 in. 3.15 in. This table converts millimeters to inches in reference to the illustrations included on these pages 68 Connector 68 Connector 8000-5130 PVC Straight 8000-5140 Right Angle Change last digit of connector number to 5 for 5 meter cable Refer to pages 116-121 for more cable information M18 Flush Mount 5mm (0.2 in.) Cable 9921-1200 M18 Non-Flush Mount 8mm (0.3 in.) 68 Cable 9921-1500 Mounting Brackets - see Pages 114-115 Cable 9921-2000 Cable 9921-2200 68 9921-1568 9921-1268 9921-1300 9921-2100 9921-1368 9921-1700 9921-2300 9921-1768 20V - 250V 50/60Hz 2 mA 500 mA 5V 2mA 8A 15Hz 15% 10% .50mm (.02 in.) PBTB Nickel Plated Brass 20V - 250V 50/60Hz 2 mA 500 mA 5V 2mA 8A 15Hz 15% 10% .50mm (.02 in.) PBTB Trogamid T 20V - 250V 50/60Hz 2 mA 500 mA 5V 2mA 8A 15Hz 15% 10% .50mm (.02 in.) PBTB Nickel Plated Brass 20V - 250V 50/60Hz 2 mA 500 mA 5V 2mA 8A 15Hz 15% 10% .8mm (.039 in.) PBTB Nickel Plated Brass 20V - 250V 50/60Hz 2 mA 500 mA 5V 2mA 8A 15Hz 15% 10% .8mm (.039 in.) PBTB Trogamid T 20V - 250V 50/60Hz 2 mA 500 mA 5V 2mA 8A 15Hz 15% 10% .8mm (.039 in.) PBTB Nickel Plated Brass Wiring Diagrams Note: Wire colors are applicable to cable purchased from Altech Fixed Cable BR Note: Sensor dimensions in mm. M LED 8 5 60 0 60 42 LED LED 8 M 18 x 1 LED M 18 x 1 7 80 0 62 18 x 1 M 18 x 1 80 Fixed Cable BR BL LOAD Yellow/GRN BL LOAD Yellow/GRN Normally Open Normally Closed Fixed Cable BR Fixed Cable BR BL LOAD BL LOAD Normally Open Normally Closed M M 18 x 1 LED 18 68 Connector Red/WHT x 1 68 Connector Red/WHT 3 2 Red GRN 1 LOAD LED 8 3 2 Red GRN LOAD 60 5 80 2 1 80 Normally Open Normally Closed Altech Corp.(R) * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 61 PREVIOUS AC - 2 WIRE - EXTENDED VOLTAGE RANGE - Brass, Nickel Plated (BN), and TROGAMID T Cylindrical,Threaded, 20-250V AC, 500 mA, 1 LED for Output Energized HOME NEXT FIND IT * IEC (529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection * Temperature Range: -25 to 70C (-13 to 158F) * Higher Current Rating * Wider Voltage Range * Carries mark M30 Flush Mount Sensing Distance Cable or Connector Style Cat. No. Normally Open Cable 9916-2600 10mm (0.39 in.) Cable 9916-2900 68 9916-2668 Normally Closed Voltage Range Operating Frequency Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Short Term Current (20 ms, 1Hz) Switching Frequency Hysterisis Temperature Drift Repeatability Front Cap Material Housing Material 9916-2100 9916-2400 9916-2168 20V-250V 50/60Hz 2 mA 500 mA 5V 2mA 8A 15Hz 15% 10% 1mm (.039 in.) PBTP Nickel Plated Brass 20V - 250V 50/60Hz 2 mA 500 mA 5V 2mA 8A 15Hz 15% 10% 1mm (.039 in.) PBTP Trogamid T 20V - 250V 50/60Hz 2 mA 500 mA 5V 2mA 8A 15Hz 15% 10% 1mm (.039 in.) PBTP Nickel Plated Brass M 30 x 1, 5 Nickel Plated Brass Housings Fixed Cable PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.) cable length, change the last two digits of the part number to 02. For other cable lengths and/or PUR cable, please consult Altech. Supplied with non-metallic locknuts for Trogamid T housings and Brass, Nickel Plated (BN) locknuts for Nickel Plated Brass housings. Trogamid T Housings LED 5 60 0 M 30 x 1, 5 LED 7 80 0 M 30 x 1, 5 LED 68 Style Connectors 3-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. 62 Altech Corp.(R) * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 80 60 PREVIOUS HOME NEXT FIND IT Accessories 2 meter (6 ft. 6 in.) AC Cable Assemblies for Quick Disconnect Sensors Metric/in. Conversion Table 1.5 mm 12.0 mm 30.0 mm 38.0 mm 48.0 mm = .06 in. = .47 in. =1.18 in. =1.50 in. =1.89 in. 50.0 mm 58.0 mm 60.0 mm 80.0 mm = = = = 1.96 in. 2.28 in. 2.36 in. 3.15 in. This table converts millimeters to inches in reference to the illustrations included on these pages 68 Connector 68 Connector 8000-5130 PVC Straight 8000-5140 Right Angle Change last digit of connector number to 5 for 5 meter cable Refer to pages 116-121 for more cable information M30 Non-Flush Mount 15mm (0.59 in.) Cable 9916-2700 Mounting Brackets - see Pages 114-115 Cable 9916-3000 68 9916-2768 9916-2300 9916-2500 9916-2368 20V - 250V 50/60Hz 2 mA 500 mA 5V 2mA 8A 15Hz 15% 10% 1.5mm (.059 in.) PBTB Nickel Plated Brass 20V - 250V 50/60Hz 2 mA 500 mA 5V 2mA 8A 15Hz 15% 10% 1.5mm (.059 in.) PBTB Trogamid T 20V - 250V 50/60Hz 2 mA 500 mA 5V 2mA 8A 15Hz 15% 10% 1.5mm (.059 in.) PBTB Nickel Plated Brass Wiring Diagrams Note: Wire colors are applicable to cable purchased from Altech Note: Sensor dimensions in mm. Fixed Cable Fixed Cable BR M 30 x 1, 5 BL LOAD Yellow/GRN BR LED BL LOAD Yellow/GRN Normally Open 38 60 12 Normally Closed M 30 x 1, 5 Fixed Cable BR Fixed Cable BR LED 12 BL LOAD BL LOAD Normally Open 80 Normally Closed 58 M 30 x 1, 5 68 Connector Red/WHT 68 Connector Red/WHT 3 2 Red GRN 1 LOAD LED 3 2 Red GRN 1 LOAD 4 80 8 12 Normally Open Normally Closed Altech Corp.(R) * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 63 PREVIOUS AC - 2 WIRE - WELD IMMUNE Brass, Nickel Plated (BN), Cylindrical,Threaded, 20-250V AC, 300mA/500mA 1 LED for Output Energized HOME NEXT FIND IT * IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection * Temperature Range: -25 to 70C (-13 to 158F) * Circuitry that protects for electro-magnetic interference * Flush models have teflon ceramic coatings to protect for weld slag * Carries mark M12 Flush Mount Sensing Distance Cable or Connector Style Cat. No. Normally Open Normally Closed Voltage Range Operating Frequency Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Short Term Current (20 ms, 1Hz) Switching Frequency (at Resistance Load of 150 mA) Hysterisis Temperature Drift Repeatability Front Cap Material Housing Material 9952-5840 M12 Non-Flush Mount 4mm (.16 in.) 48 Cable 9952-5900 2mm (.08 in.) Cable 9952-5848 68 9952-5968 9952-5640 9952-5648 9952-5700 9952-5768 20V-250V 50/60Hz 2 mA 300 mA 5V 2 mA 2A 15 Hz 15% 10% 20V - 250V 50/60Hz 2 mA 300 mA 5V 2 mA 2A 15 Hz 15% 10% .10mm (.004 in.) Teflon Teflon Plated Brass 20V - 250V 50/60Hz 2 mA 300 mA 5V 2 mA 2A 15Hz 15% 10% .2mm (.008 in.) PBTB Nickel Plated Brass 20V - 250V 50/60Hz 2 mA 300 mA 5V 2 mA 2A 15 Hz 15% 10% .2mm (.008 in.) PBTB Nickel Plated Brass .10mm (.004 in.) Teflon Teflon Plated Brass M 12 x 1 10 Fixed Cable PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.) cable length, change the last two digits of the part number to 02. For other cable lengths and/or PUR cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. LED 70 M 12 x 1 LED 48/68 Style Connector 3-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. 64 Altech Corp.(R) * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 10 80 6 6 PREVIOUS HOME NEXT FIND IT Accessories 2 meter (6 ft. 6 in.) AC Cable Assemblies for Quick Disconnect Sensors Metric/in. Conversion Table 1.0 mm 6.0 mm 8.0 mm 10.0 mm 12.0 mm 18.0 mm 60.0 mm 70.0 mm 80.0 mm = .04 in. = .23 in. = .31 in. = .39 in. = .47 in. = .70 in. =2.36 in. =2.75 in. =3.15 in. This table converts millimeters to inches in reference to the illustrations included on these pages 48/68 Connector 8000-5130 PVC, Straight 48/68 Connector 8000-5140 Right Angle Change last digit of connector number to 5 for 5 meter cable Refer to pages 116-121 for more cable information M18 Flush Mount 5mm (.20 in.) Cable 9954-5840 M18 Non-Flush Mount 8mm (.31 in.) Mounting Brackets - see Pages 114-115 68 9954-5968 48 9954-5848 Cable 9954-5900 9954-5640 9954-5648 9954-5700 9954-5768 20V - 250V 50/60Hz 2 mA 500 mA 5V 2 mA 8A 15 Hz 15% 10% .25mm (.01 in.) Teflon Teflon Plated Brass 20V - 250V 50/60Hz 2 mA 500 mA 5V 2 mA 8A 15 Hz 15% 10% .25mm (.01 in.) Teflon Teflon Plated Brass 20V - 250V 50/60Hz 2 mA 500 mA 5V 2 mA 8A 15 Hz 15% 10% .4mm (.016 in.) PBTB Nickel Plated Brass 20V - 250V 50/60Hz 2 mA 500 mA 5V 2 mA 8A 15 Hz 15% 10% .4mm (.016 in.) PBTB Nickel Plated Brass Note: Sensor dimensions in mm. Wiring Diagrams Note: Wire colors are applicable to cable purchased from Altech M M 1 18 x x 1 Fixed Cable BR LED 8 BL LOAD 60 Yellow/GRN Normally Open 10 M M 18 18 x 1 48/68 Connector Red/WHT LED 8 3 2 Red GRN LOAD 80 1 Altech Corp.(R) * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 10 Normally Open 65 PREVIOUS AC - 2 WIRE - WELD IMMUNE Brass, Nickel Plated (BN), Cylindrical,Threaded, 20-250V AC, 300/500mA 1 LED for Output Energized HOME NEXT FIND IT * Circuitry that protects for electro-magnetic interference * Flush models have teflon ceramic coatings to protect for weld slag * Carries mark * IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection * Temperature Range: -25 to 70C (-13 to 158F) M30 Flush Mount Sensing Distance Cable or Connector Style Cat. No. Normally Open Normally Closed Voltage Range Operating Frequency Supply Current Max. Load Current Voltage Drop Across Sensor Max. Leakage Currrent Short Term Current (20 ms, 1Hz) Switching Frequency (at Resistance Load of 150 mA) Hysterisis Temperature Drift Repeatability Front Cap Material Housing Material 9956-5840 M30 Non-Flush Mount 15mm (.59 in.) Cable 9956-5900 10mm (.39 in.) Cable 48 9956-5848 68 9956-5968 9956-5640 9956-5648 9956-5700 9956-5768 20V-250V 50/60Hz 2 mA 500 mA 5V 2 mA 8A 15 Hz 15% 10% .5mm (.02 in.) Teflon Teflon Plated Brass 20V - 250V 50/60Hz 2 mA 500 mA 5V 2 mA 8A 15 Hz 15% 10% .5mm (.02 in.) Teflon Teflon Plated Brass 20V - 250V 50/60Hz 2 mA 500 mA 5V 2 mA 8A 15 Hz 15% 10% .75mm (.03 in.) PBTB Nickel Plated Brass 20V - 250V 50/60Hz 2 mA 500 mA 5V 2 mA 8A 15Hz 15% 10% .75mm (.03 in.) PBTB Nickel Plated Brass Note: Sensor dimensions in mm. M 30 x 1, 5 Fixed Cable PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.) cable length, change the last two digits of the part number to 02. For other cable lengths and/or PUR cable, please consult Altech. Supplied with Brass, Nickel Plated (BN) locknuts. LED 10 80 12 M 30 x 1, 5 66 Altech Corp.(R) * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 10 80 12 48/68 Style Connector 4-pin, Micro style, 12mm (.47 in.) supplied with Brass, Nickel Plated (BN) locknuts. LED PREVIOUS Metric/in. Conversion Table 1.5 mm 10.0 mm 12.0 mm 30.0 mm 80.0 mm = .06 in. = .39 in. = .47 in. =1.18 in. =3.15 in. HOME NEXT FIND IT This table converts millimeters to inches in reference to the illustrations included on these pages Accessories 2 meter (6 ft. 6 in.) DC Cable Assemblies for Quick Disconnect Sensors 48/68 Connector 8000-5130 PVC, Straight 48/68 Connector 8000-5140 Right Angle Change last digit of connector number to 5 for 5 meter cable Refer to pages 116-121 for more cable information Mounting Brackets - see Pages 114-115 Wiring Diagrams Note: Wire colors are applicable to cable purchased from Altech Fixed Cable BR BL LOAD Yellow/GRN Normally Open 48/68 Connector Red/WHT 3 2 Red GRN 1 LOAD Normally Open Altech Corp.(R) * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908) 806-9400 * Fax (908) 806-9490 67 |
Price & Availability of 9914-0500 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |